Makita DHR400ZKUN без акк. и з.у [12/100] Indicating the remaining battery capacity

Makita DHR400ZKUN без акк. и з.у [12/100] Indicating the remaining battery capacity
12 ENGLISH
Indicating the remaining battery
capacity
Only for battery cartridges with the indicator
►Fig.2: 1. Indicator lamps 2. Check button
Pressthecheckbuttononthebatterycartridgetoindi-
catetheremainingbatterycapacity.Theindicatorlamps
lightupforafewseconds.
Indicator lamps Remaining
capacity
Lighted Off Blinking
75% to 100%
50% to 75%
25% to 50%
0% to 25%
Charge the
battery.
Thebattery
mayhave
malfunctioned.
NOTE:Dependingontheconditionsofuseandthe
ambienttemperature,theindicationmaydifferslightly
fromtheactualcapacity.
Tool / battery protection system
Thetoolisequippedwithatool/batteryprotectionsys-
tem.Thissystemautomaticallycutsoffpowertothe
motortoextendtoolandbatterylife.Thetoolwillauto-
maticallystopduringoperationifthetoolorbatteryis
placedunderoneofthefollowingconditions:
Overload protection
Whenthebatteryisoperatedinamannerthatcauses
ittodrawanabnormallyhighcurrent,thetoolautomat-
icallystopswithoutanyindication.Inthissituation,turn
thetooloffandstoptheapplicationthatcausedthetool
tobecomeoverloaded.Thenturnthetoolontorestart.
Overheat protection
Whenthetoolorbatteryisoverheated,thetoolstops
automaticallyandthelampblinks.Inthiscase,letthe
toolandbatterycoolbeforeturningthetoolonagain.
Overdischarge protection
Whenthebatterycapacityisnotenough,thetoolstops
automatically.Inthiscase,removethebatteryfromthe
toolandchargethebattery.
Switch action
WARNING: Before installing the battery car-
tridge into the tool, always check to see that the
switch trigger actuates properly and returns to
the "OFF" position when released.
CAUTION: When not operating the tool,
depress the trigger-lock button from side to
lock the switch trigger in the OFF position.
►Fig.3: 1.Switchtrigger2.Trigger-lockbutton
Topreventtheswitchtriggerfromaccidentallypulled,
thetrigger-lockbuttonisprovided.Tostartthetool,
depressthetrigger-lockbuttonfromAsideandpullthe
switchtrigger.Releasetheswitchtriggertostop.After
use,pressinthetrigger-lockbuttonfromBside.
Speed change
Therevolutionsandblowsperminutecanbeadjusted
byturningtheadjustingdial.Thedialismarked1(low-
estspeed)to5(fullspeed).
►Fig.4: 1.Adjustingdial
Refertothetablebelowfortherelationshipbetweenthe
numberontheadjustingdialandtherevolutionsand
blows per minute.
Number Revolutions per
minute
Blows per minute
5 500 2,900
4 470 2,700
3 380 2,150
2 290 1,650
1 250 1,450
CAUTION: Do not turn the adjusting dial when
the tool is running. Failure to do so may result in
the loss of control of the tool and cause an injury.
NOTICE: If the tool is operated continuously at
low speed for a long time, the motor will get over-
loaded, resulting in tool malfunction.
NOTICE: The speed adjusting dial can be turned
only as far as 5 and back to 1. Do not force it past
5 or 1, or the speed adjusting function may no
longer work.
NOTE:Whenthespeedadjustingdialissetto"3"or
higher,thetoolautomaticallyreducesthespeedat
no-load to reduce the vibration under no-load. Once
operation starts with a bit against concrete, blows per
minute increase and reach the numbers as shown in
the table. When temperature is low and there is less
uidityingrease,thetoolmaynothavethisfunction
even with the motor rotating.