Soler&Palau Silent-100 CZ Design Barcelona [12/60] Before installing and wiring
![Soler&Palau Silent-100 CZ Red Design 4С [12/60] Before installing and wiring](/views2/1186828/page12/bgc.png)
The SILENT DESIGN extractor fan range
is manufactured to the high standards of
production and quality as laid down by the
international Quality Standard ISO 9001.
All components have been checked and
every one of the fi nal products will have
been individually tested at the end of the
manufacturing process.
On receipt of the product we recommend
that you to check the following:
1- That it is the correct model.
2- That the details on the rating label are
those you require: voltage, frequency...
The installation must be carried out in
accordance with the electrical standards
in force in your country.
Before installing and wiring
the unit, ensure that the main supply is
disconnected.
Fig. 1:
1- Protection grille
2- Connection terminals
3- Outlet with backdraught shutter
4- Cable entry
The SILENT DESIGN is suitable for wall or
ceiling mounting and can either discharge
directly to the outside or via an individual
ducting system (see Fig.2).
The unit can be mounted on the wall or
ceiling using
the 4 rubber blocks and the
screws provided.
Make a hole in the wall or ceiling of
diameter:
- SILENT-100 DESIGN: 105 mm
- SILENT-200 DESIGN: 125 mm
If the unit is to be installed with indi-
vidual ducting, use a standard duct of
diameter:
- SILENT-100 DESIGN: 100 mm
- SILENT-200 DESIGN: 125 mm
- SILENT-300 DESIGN: 160 mm.
- SILENT-300 DESIGN: 150 / 160 mm.
Ensure that there are no obstructions to the
airfl ow and that the impeller turns freely.
Fix the extractor to the wall in such a way
that it is not distorted in order to avoid
noise generation or problems with the
rotation of the impeller. Make sure that the
backdraught shutter opens freely and has
not being damaged in transit. Introduce
the mains cable through the cable entry
(4) and fi x it to the wall.
Connect the electrical wiring as set out
below and then mount the protection
grille (1).
The SILENT DESIGN is an extractor
designed for a single phase supply, with
voltage and frequency as indicated on
the rating plate of the unit. The units
are manufactured with double electrical
insulation (Class II) and therefore they do
not need an earth connection.
The electrical installation must include a
double pole switch with a contact clear-
ance of at least 3 mm.
The electrical cable must enter the SILENT
DESIGN through the cable entry (4).
Once the cable has been introduced pro-
ceed using the electrical wiring diagram
applicable to the selected model.
SILENT CZ DESIGN
For these models use the following
diagrams:
Fig.3: Switching the extractor through
the light switch.
Fig.4: To switch the fan through an inde-
pendent switch.
Содержание
- Ct 12 14 7
- Silent 100 cz design 12v 7
- Instrucciones del usuario este aparato pueden utilizarlo niños con edad de 8 años y superior y personas con capacidades físicas sensoriales o mentales reducidas o falta de experiencia y conocimiento si se les ha dado la supervisión o formación apropiadas respecto al uso del aparato de una manera segura y comprenden los peligros que implica los niños no deben jugar con el aparato la limpieza y el manteni miento a realizar por el usuario no deben realizarlos los niños sin supervisión 11
- Before installing and wiring 12
- Directly to the outside or via an individual ducting system see fig 12
- Fig 1 1 protection grille 2 connection terminals 3 outlet with backdraught shutter 4 cable entry 12
- Make a hole in the wall or ceiling of diameter silent 100 design 105 mm silent 200 design 125 mm 12
- On receipt of the product we recommend that you to check the following 12
- Silent 300 design 160 mm 12
- That it is the correct model 2 that the details on the rating label are those you require voltage frequency 12
- The installation must be carried out in accordance with the electrical standards in force in your country 12
- The silent design extractor fan range is manufactured to the high standards of production and quality as laid down by the international quality standard iso 9001 all components have been checked and every one of the fi nal products will have been individually tested at the end of the manufacturing process 12
- The silent design is suitable for wall or ceiling mounting and can either discharge 12
- The unit can be mounted on the wall or ceiling using the 4 rubber blocks and the screws provided 12
- The unit ensure that the main supply is disconnected 12
- Assistenza tecnica in caso di anomalie di funzionamento vogliate contattare il vostro distributore 28
- Manutenzione è necessaria solo una pulizia periodica dell aspiratore con uno straccio imbevuto di un detersivo leggero 28
- Qualsiasi intervento di cui l apparecchio sia oggetto ad opera di persone estranee ai servizi uffi ciali della s p ci costringe rebbe ad annullarne la garanzia 28
- S p si riserva il diritto di introdurre mo difi che senza preavviso 28
- لاس ب ا 55
- أ يس تنلياس زارطر دز 56
- ةلاح2 56
- دز شتأ يس تنلياس زارط 56
- دز يس تنلياس زارط 56
- لاح2 56
- تنلياس زارط900 92 تلوف 57
- S p sistemas de ventilación s l u 60
Похожие устройства
- Soler&Palau Silent-100 CZ Red Design 4С Инструкция по эксплуатации
- Soler&Palau SILENT-200 CZ CHAMPAGNE DESIGN-4C Инструкция по эксплуатации
- Soler&Palau SILENT-200 CZ DESIGN-3C Инструкция по эксплуатации
- Soler&Palau SILENT-200 CZ GOLD DESIGN - 4C Инструкция по эксплуатации
- Soler&Palau SILENT-200 CZ SILVER DESIGN-3C Инструкция по эксплуатации
- Soler&Palau TD-160\100NT Silent Инструкция по эксплуатации
- Soler&Palau TD-350\125 Инструкция по эксплуатации
- Soler&Palau Vent-100L Инструкция по эксплуатации
- Soler&Palau Vent-125L Инструкция по эксплуатации
- Soler&Palau Vent-160L Инструкция по эксплуатации
- Soler&Palau Vent-200L Инструкция по эксплуатации
- Сварог TIG TS 26 (200AC/DC (E201) 8м IOW8004-20 Инструкция по эксплуатации
- Сварог PRO TS 18 (250,315AC/DC) 8м IOB6367-sv001 Инструкция по эксплуатации
- Сварог PRO TS 26 (160,200AC/DC) 8м IOW6360-sv001 Инструкция по эксплуатации
- Сварог PRO TS 26 М12х1 8м IOW6306-sv001 Инструкция по эксплуатации
- Сварог TECH SUPER TS 18 М12х1 8м IOB66306-00 Инструкция по эксплуатации
- Сварог TECH TS 18 (250,315AC/DC) 8м IOB6367 Инструкция по эксплуатации
- Сварог TIG SUPER TS 18 (400,500,500PAC/DC) 4м IOB66960-20 Инструкция по эксплуатации
- Сварог TIG SUPER TS 20 М12х1 8м IOM66306-00 Инструкция по эксплуатации
- Сварог TIG TS 18 (315) 8м IOB6361 Инструкция по эксплуатации