Vorel 81783 карманный [5/6] O p e r a t i n g m a n u a l
![Vorel 81784 карманный [5/6] O p e r a t i n g m a n u a l](/views2/1886316/page5/bg5.png)
OPERATING MANUAL
5
GB
seen if the measurement leads of the meter are short-circuited.
Measurement of capacitance
Switch the range selector to the position of the measurement of capacitance. Make sure the capacitor was discharged
before the measurement. Do not ever measure the capacitance of a charged capacitor, since it might damage
the meter and cause an electric shock.
Measurements of frequency
Connect the measurement cables to the sockets marked as „VΩ” and „COM”; switch the range selector to the posi-
tion of measurement of frequency. Put the measurements leads to the terminals of the tested element and read the
result of the measurement in the display. Do not ever measure the frequency of a signal whose frequency exceeds
250V RMS (average value). The measured signal should not exceed 100V RMS, since otherwise the result cannot
be read.
Measurement of temperature
Connect the special cable to the TEMP socket and observe the polarization of the terminals. Switch the range selector
to the position of measurements of temperature. Measure the temperature with the other end of the thermoelement.
The meter will indicate the temperature in degrees centigrade. The thermoelement supplied with the device permits to
realise measurements only up to 250
O
C. Measurements up to 300
O
C are permitted provided the duration of measure-
ments is short.
Diode and conductivity test
Connect the measurement cables to the sockets marked as „VΩ” and „COM”, and switch the selector to the diode
symbol. Place the measurement leads at the diode terminals in the conduction direction and the reverse direction. If
the diode is functioning correctly, then at the diode connected in the forward direction we will read the voltage drop for
this diode expressed in mV. In case the diode is connected in the reverse direction the display will read „1”. If the diode
terminal is damaged the display will read „0” independently of the direction in which the diode is connected. Correctly
functioning diodes show a low resistance in the forward direction and a high resistance in the reverse direction. It is
strictly prohibited to test live diodes.
In case the meter is used for conduction measurements, the internal buzzer will emit sound each time the measured
resistance drops below 30±10Ω.
Transistor test
Switch the measurement range selector to the position marked with the h
FE
symbol (measurement of the gain coef-
ficient of the transistor). Depending on the type of transistor it must be connected to the socket of the base marked
as PNP or NPN, making sure the terminals of the transistor are placed in accordance with the letter indications: E
- emitter, B - base, C - collector. If the transistor is functioning properly and the connection is correct, the result of the
measurement of the gain coefficient is read in the display. It is strictly prohibited to test live transistors.
Содержание
- Digital multimeter 1
- 20 μf 2
- Attention it is prohibited to measure electrical quantities exceeding the maximum measurement range of the meter 3
- Attention the meter is not a measurement device as it is construed within the measurement law 3
- Before using the meter read the whole manual and keep it 3
- O p e r a t i n g m a n u a l 3
- Properties of the device 3
- Technical properties 3
- The all purpose meter is a digital measurement device designed to measure various electrical quantities the meter has been designed for amateur non professional purposes and must not be used for paid jobs or craft 3
- The meter has a plastic housing a liquid crystal display and a measurement range selector the housing is equipped with three measurement sockets and a transistor test socket the meter is equipped with measurement cables with plugs the meter is sold without a battery 3
- O p e r a t i n g m a n u a l 4
- O p e r a t i n g m a n u a l 5
- 95 ec low voltage equipment 2004 108 ec electromagnetic compatibility emc directive 6
- And fulfill requirements of the following european directives 6
- Declaration of conformity 6
- Digital universal multimeter item no 81783 digital universal multimeter item no 81784 6
- En 61010 1 2001 en 61010 031 2002 a1 2008 en 61326 1 2006 en 61326 2 2006 6
- Meet requirements of the following european standards technical specifications 6
- The last two digits of the year in which the ce marking was affixed 07 year of production 2012 6
- We declare and guarantee with full responsibility that the following products 6
- Wrocław 2012 1 2 6
Похожие устройства
- Stihl SG71 (42550194970) Инструкция по эксплуатации
- Stihl BGA 56 Set Инструкция по эксплуатации
- Stihl MSA 120 C-BQ Set Инструкция по эксплуатации
- Greenworks GSP1250K2 (5103507UB) Инструкция по эксплуатации
- Bosch Газонокосилка ARM 37 (06008A6201) +Топор X7-XS Инструкция по эксплуатации
- Duwi 26049 3 Инструкция по эксплуатации
- Bosch GLM 50 C + фитнес-браслет (06159940LS) Инструкция по эксплуатации
- Bosch GLM 80 + футбольный мяч (06159940LN) Инструкция по эксплуатации
- Bosch Дальномер GLM 50C (0601072C00) +Мышь Logitech M280 Инструкция по эксплуатации
- Bosch Дальномер GLM 80 (0601072300) +Мышь Logitech M280 Инструкция по эксплуатации
- МЕГЕОН 15002 цифровой карманный Инструкция по эксплуатации
- Husqvarna 120 Mark II 16'' Инструкция по эксплуатации
- Джилекс КРАБ-Т 100 (9092) Инструкция по эксплуатации
- Stihl MSA 140 C-BQ SET (12540115858) Инструкция по эксплуатации
- Greenworks GES13 + Пила цепная GCS1836 Инструкция по эксплуатации
- Condtrol Omniliner 3D G (1-2-153) Инструкция по эксплуатации
- Denzel 58235 Инструкция по эксплуатации
- Worx WG260E.9 без акк. и з.у Инструкция по эксплуатации
- Worx WG629E.9 без акк. и з.у Инструкция по эксплуатации
- Gardena 15103-32.000.00 Инструкция по эксплуатации