Orient ОС-101 [124/244] Message id

Orient ОС-201 [124/244] Message id
COMNAV OEM BOARD REFERENCE MANUAL
Chapter 4. Logs Messages
ComNav Technology Ltd.
105
CNT-OEM-RM001, Rev 1.8
(normal, minimum), air pressure (normal, maximum and minimum), water pressure, dew-point
temperature, battery voltage, mainboard temperature etc.
Message ID
108
Recommended Input
log meteodataexta ontime 60
Supported Format
ASCII, Binary
Reply (ASCII)
#METEODATAEXTA,COM1,0,60.0,FINESTEERING,1856,352733.000,00000000,0000,
1114;TMQD,20150803,135200,00007,30.5,31.1,130900,30.5,135100,0,0,13090
0,1006.0,1006.5,130900,1006.0,134800,0.0,0.0,12.0,32.6*3B1FCCAA
Field#
Field Type
Format
Binary
Byte
Binary
Offset
1
METEODATAEXT header
H
0
2
Data Indicator
UShort
2
H
3
Year, Month, Day
ULong
4
H+2
4
Hour, Minute, Second
ULong
4
H+6
5
Sensor ID
ULong
4
H+10
6
Temperature
Float
4
H+14
7
Max Temp
Float
4
H+18
8
Max Temp Time
ULong
4
H+22
9
Min Temp
Float
4
H+26
10
Min Temp Time
ULong
4
H+30
11
Humidity
UShort
2
H+34
12
Min Humidity
UShort
2
H+36
13
Min Humidity Time
ULong
4
H+38
14
Air Pressure
Float
4
H+42
15
Max Air Pressure
Float
4
H+46
16
Max Air Pressure Time
ULong
4
H+50
17
Min Air Pressure
Float
4
H+54
18
Min Air Pressure Time
ULong
4
H+58