Pedrollo TS2 - MK 5/8 [11/12] Application limits

Pedrollo TS2 - MK 3/5 [11/12] Application limits
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210
0
10
20
30
40
50
60
70
80
90
100
110
0
50
100
150
200
250
300
0 10 20 30 40 50
0 10 20 30 40
0 1 2 3 4 5 6 7 8 9 10 11 12
US g.p.m.
Imp g.p.m.
feet
l/min
m³/h
T
S
2
-
P
L
U
R
I
J
E
T
1
3
0
T
S
2
-
P
L
U
R
I
J
E
T
9
0
T
S
2
-
P
L
U
R
I
J
E
T
2
0
0
MODEL POWER MAX PERFORMANCES PERFORMANCES (ADJUSTABLE SET POINT)
P2 Q H Min. Set Point Set Point Stand. Setting Max. Set Point
Single-phase kW HP
l/min metres bar l/min bar l/min bar l/min
TS2-PLURIJET 5/90 1.1 1.5
IE3
5 – 90 78 – 38 2.80 5 – 75 5.30 5 – 65 7.10 5 – 23
TS2-PLURIJET 6/90 1.5 2 5 – 90 94 – 45 3.40 5 – 75 6.30 5 – 65 8.60 5 – 21
TS2-PLURIJET 3/130 1.1 1.5 5 – 130 49 – 24 1.80 5 – 110 3.40 5 92 4.30 5 – 48
TS2-PLURIJET 4/130 1.5 2 5 – 130 65 – 31 2.30 5 – 110 4.40 5 – 92 5.80 5 – 45
TS2-PLURIJET 5/130 1.8 2.5 5 – 130 81 – 39 2.90 5 – 110 5.50 5 – 92 7.40 5 – 38
TS2-PLURIJET 6/130 2.2 3 5 – 130 97 – 45 3.50 5 – 110 6.50 5 – 92 9.00 5 – 33
TS2-PLURIJET 3/200 1.1 1.5 5 – 200 43 – 13 1.60 5 – 185 2.80 5 133 3.80 5 – 72
TS2-PLURIJET 4/200 1.5 2 5 – 200 57 – 17 2.10 5 – 185 3.60 5 133 5.10 5 – 65
TS2-PLURIJET 5/200 1.8 2.5 5 – 200 72 – 22 2.60 5 – 185 4.60 5 133 6.50 5 – 56
TS2-PLURIJET 6/200 2.2 3 5 – 200 86 – 26 3.10 5 – 185 5.50 5 133 7.9 0 5 – 45
PERFORMANCE RANGE
APPLICATION LIMITS
Manometric suction lift up to 9 m
Liquid temperature between -10 °C and +40 °C
Ambient temperature up to +40 °C
Max. working pressure 10 bar
Continuous service S1
CLEAN WATER
DOMESTIC USE
CIVIL USE
Flow rate Q
4
Head H (metres)
4
Q = Flow rate H = Total manometric head Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
 
Three phase motor eciency class (IEC 60034-30-1)