VTS VENTUS N-type NVS 65 WC3.V [9/13] Control system
![VTS VENTUS N-type NVS 39 PG4 [9/13] Control system](/views2/1894818/page9/bg9.png)
CONSTRUCTION:
600 mm lter bags in a 25 mm
thick frame.
The lter fabric is made
of polyester bre.
Vertical arrangement of the lter bags.
Installation: System of guides allows
for the quick and easy replacement
of the lters.
FUNCTIONS AND APPLICATION:
Final lters for ventilation and air
conditioning systems with high
air purity requirements.
Ducted bag lter (B.F7)
Size
Filter
type
Filter properties
Filter dimensions
W
i
x H
i
x B
i
Frontal cross-sectional
area
Filter area
[mm] x [mm] x [mm] [m
2
] [m
2
]
NVS 23
F7
592x287x600 0.17 3.13
NVS 39 592x428x600 0.25 4.68
NVS 65
428x490x600
0.35 6.28
287x490x600
NVS 80
428x592x600
0.51 8.66
428x592x600
FUNCTIONS AND APPLICATION:
Air ow cut-off through
the air handling unit.
Air ow adjustment through
the air handling unit.
Air mixing rate adjustment
in the supply and exhaust air
handling units.
OPTIONAL ELEMENTS
Air damper
CONSTRUCTION:
The blades are made
of constructional plastic (ASA),
with the edges protected with seals
of soft composite material.
The blades rotate in pairs
in opposing directions.
Aluminium frame.
The drive is realized by means
of composite gears installed inside
the damper’s frame.
The damper is equipped with a square
stem tted for actuator installation.
FUNCTIONS AND APPLICATION:
Protection of the ventilation system
(ducts) from vibrations transferred
from the air handling unit.
Compensation of ventilation ducts’
misalignment in relation to the axis
of the air handling unit.
Flexible connection
CONSTRUCTION:
Flange: PVC-C material
with UV stabilizer.
Ambient temperature:
from -30°C to 97°C. Fire resistance
UL 94HB [ISO 1210].
Composite material: PVC coated
polyester fabric. Ambient temperature:
from -30°C to 70°C.
Flexible connections are to be tted
with an earthing wire to balance
the electric potential.
The professional control system is offered along with the air handling units of VENTUS N-TYPE series. It ensures easy
control over ventilation and air conditioning systems and results in failure-free operation. Desired air parameters
are achieved at minimal costs. The heart of control system is integrated with HMI OPTIMA user interface. It ensures
unprecedented convenience and simplicity of air parameters adjustment.
FUNCTIONS AND APPLICATION:
Setting and reading the parameters
of the air handling unit.
Selection and conguration
of the operating mode.
Operating calendar settings.
Information on the alarm status
and possibility of its cancellation.
CONTROL SYSTEM
OPERATING PARAMETERS:
Supply voltage: 230 V AC.
Frequency: 50 Hz ± 1 Hz.
Supply voltage in the control circuits:
24 V AC.
Protection degree: IP20.
Operating environment temperature:
from 0°C to +40°C.
HMI OPTIMA - USER INTERFACE
FUNCTIONS AND APPLICATION:
Measurement of the temperature
of supply air, exhaust air or external air.
Protection of maximum
and minimum supply air temperature.
OPERATING PARAMETERS:
Measurement: from -50°C to +110°C,
Measurement accuracy: ±0,5 K.
Measuring element: PT1000,
output signal: resistance.
Communication cable length:
maximum 150 m.
Protection degree: IP67.
DUCT TEMPERATURE SENSOR
CONSTRUCTION:
Resistive measuring element installed
in the aluminium 25 cm long
bayonet probe.
Ducted bag lter specications (B.F7)
16
17
Содержание
- Duct air conditioning 1
- Continents 27 countries 2
- Iso 9001 iso 14001 2
- Vts group 2
- You can trust 2
- Defender air curtain 3
- Maximum air flow rate for the sections 3
- Maximum air flow velocity in the cross section m s 3
- Ventus air handling units 3
- Ventus n type functions 3
- Volcano water heater 3
- Vts product range 3
- 39 65 80 4
- Advantages 4
- Air filtration 4
- Application 4
- Attractive price 4
- Base and additional functions 4
- Base units 4
- Control system 4
- Heat recovery function 4
- Heating 4
- Monocoque frameless housing 4
- N cad selection program 4
- Noise attenuation 4
- On stock availability 4
- Plug fan type fan assembly 4
- Size of ahu 4
- Sport facilities garages dwelling houses service centres trading centres industrial facilities 4
- Symbols and coding 4
- 12 12 13 13 14 14 15 16 5
- 17 18 18 18 19 5
- 20 20 21 5
- 22 23 23 5
- Advantages application 5
- Base and additional functions 5
- Brand you can trust 5
- Construction of the sections 5
- Control system 5
- Dimensions of the sections and functional elements 5
- Fan charts 5
- Fan performance nvs 23 fan performance nvs 39 fan performance nvs 65 fan performance nvs 80 5
- Fan section ventilation cooling section with a water cooling coil cooling section with a direct expansion cooling coil ducted water heating coil electric heater noise attenuation panels cross flow heat recuperator air filters optional elements 5
- Hmi optima user interface duct temperature sensor strap on return water temperature sensor differential pressure switch over heating protection thermostat on off and on off s electric air amper actuator and electric air damper actuator with return spring anti frost thermostat on air side three port valve with electric actuator frequency converter inverter control gears for supply and supply exhaust n type air handling units thyristor speed controllers tr 600 tr 900 tr 2000 5
- Symbols and coding 5
- Table of contents 5
- Ventus n type functions 5
- Vts group 5
- Vts product range 5
- Construction of the sections 6
- Dimensions of the sections and functional elements 6
- Fan section ventilation 6
- Fan sets 6
- Single phase motor ratings 6
- Three phase motor ratings 6
- Air dehumidification 7
- As a standard the heater is equipped with a thermostat to protect from overheating 7
- Composition 7
- Construction 7
- Cooling of the air supplied to the room 7
- Cooling section characterisitic data 7
- Cooling section with a direct expansion cooling coil 7
- Cooling section with a water cooling coil 7
- Copper tubes with embedded aluminium fins cu al 7
- Copper tubes with fixed aluminium lamellas cu al 7
- Direct driven plug fan with a water coil cooler in insulated casing 7
- Direct expansion cooling coil section 7
- Duct water heater characteristic data 7
- Ducted water heating coil 7
- Electric heater 7
- Electric heater dimensions 7
- Functions and application 7
- Heating elements are connected in groups each with a capacity of 18 kw 7
- Heating of the air after the dehumidification process 7
- Heating of the air after the dehumidification process in the summer 7
- Heating of the air supplied to a room 7
- Heating of the air supplied to the room 7
- Maximum content of glycol 50 7
- Maximum operating pressure of the medium 1 mpa 16 bar test 21 bar 7
- Maximum operating pressure of the medium 2 mpa 22 bar tested 29 bar 7
- Minimum air flow velocity v 1 m s maximum allowable ambient temperature around the heating elements 65 c 7
- Plug fan and direct expansion dx cooling coil in an insulated casing 7
- The assembly of the resistance heating elements made of cr ni fe alloy each with 6 kw 400 v capacity 7
- The combination of a fan set with a cooler in one block provides the high tightness and strength of the section the construction ensures that the fan and the cooling coil are perfectly matched 7
- The combination of a fan set with a cooler in one block provides the high tightness and strength of the section the construction ensures that the fan assembly is properly connected to the cooler 7
- The required heating power can be obtained through a flexible regulation system or through a gradual adjustment wiring diagram available in the operating manual 7
- The unit consists of a fan set a three row direct expansion cooling coil with a droplet eliminator a monocoque casing that provides perfect thermal insulation high rigidity and a drainage system for condensing water 7
- The water section consists of a fan set a three row cooling coil with droplet eliminator and monocoque casing that provides perfect thermal insulation high rigidity and a drainage system for condensing water 7
- Tube diameter ½ minimum temperature of the medium for ice water 3 c 7
- Tube diameter ½ number of r rows 3 minimum ice water temperature 5 c maximum operating pressure of the medium 1 mpa 16 bar tested 21 bar 7
- Tube diameter ½ number of rows 2 maximum temperature of the medium heat carrier 150 c automatics up to 140 c 7
- Water cooler 7
- Air filters 8
- Cross flow heat recuperator 8
- Cross flow recuperator dimensions 8
- Cross flow recuperator specifications 8
- Ducted bag filter b f5 8
- Ducted bag filter specifications b f5 8
- Ducted panel filter p g4 8
- Muffler specifications 8
- Noise attenuation panels 8
- Sectional filter specifications 8
- Air damper 9
- Control system 9
- Duct temperature sensor 9
- Ducted bag filter b f7 9
- Ducted bag filter specifications b f7 9
- Flexible connection 9
- Hmi optima user interface 9
- Optional elements 9
- Anti frost thermostat on air side 10
- Differential pressure switch 10
- On off and on off s electric air amper actuator and electric air damper actuator 10
- Over heating protection thermostat 10
- Strap on return water temperature sensor 10
- With return spring 10
- Control gears for supply and supply exhaust n type air handling units 11
- Dimensions of control gears designed for applications without frequency converters dimensions of control gears and automation designed for applications with frequency converters 11
- Frequency converter 11
- Inverter 11
- Three port valve with electric actuator 11
- Thyristor speed controllers 11
- Thyristor speed controllers operational parameters 11
- Tr 600 tr 900 tr 2000 11
- F v м3 ч 12
- Fan charts 12
- Fan performance nvs 23 12
- Fan performance nvs 39 12
- Fan performance nvs 65 12
- Fan performance nvs 80 12
- Nvs 65 12
- Vs 355 12
- Www vtsgroup com 13
Похожие устройства
- VTS VENTUS N-type NVS 65 WC3.V Сертификат
- VTS VENTUS N-type NVS 65 DX3.1.V Инструкция по эксплуатации
- VTS VENTUS N-type NVS 65 DX3.1.V Инструкция по инсталляции
- VTS VENTUS N-type NVS 65 DX3.1.V Брошюра
- VTS VENTUS N-type NVS 65 DX3.1.V Сертификат
- VTS VENTUS N-type NVS 65 WH3 Инструкция по эксплуатации
- VTS VENTUS N-type NVS 65 WH3 Инструкция по инсталляции
- VTS VENTUS N-type NVS 65 WH3 Брошюра
- VTS VENTUS N-type NVS 65 WH3 Сертификат
- VTS VENTUS N-type NVS 65 WH2 Инструкция по эксплуатации
- VTS VENTUS N-type NVS 65 WH2 Инструкция по инсталляции
- VTS VENTUS N-type NVS 65 WH2 Брошюра
- VTS VENTUS N-type NVS 65 WH2 Сертификат
- VTS VENTUS N-type NVS 65 EH54 Инструкция по эксплуатации
- VTS VENTUS N-type NVS 65 EH54 Инструкция по инсталляции
- VTS VENTUS N-type NVS 65 EH54 Брошюра
- VTS VENTUS N-type NVS 65 EH54 Сертификат
- VTS VENTUS N-type NVS 65 PG4 Инструкция по эксплуатации
- VTS VENTUS N-type NVS 65 PG4 Инструкция по инсталляции
- VTS VENTUS N-type NVS 65 PG4 Брошюра