Graco Reactor E-20 PH9034 [72/76] Not for sale
Превью страниц
Страница 72 /
76
![Graco Reactor E-20 259034 [72/76] Not for sale](/views2/1900107/page72/bg48.png)
Parts
72 312066ZAF
Circuit Breaker Modules Parts List
--- Not for sale.
† For models series A - E.
‡ For models series F - G
Ref. Description
Breaker Modules
Qty.
E-20 and EXP-1 Models E-30 and EXP-2 Models
A
230V,
3 phase
B
400V,
3 phase
C
230V,
1 phase
D
230V,
3 phase
E
400V,
3 phase
F
230V,
1 phase
901 RAIL, mounting
255028 255028 255028 255028 255028 255028 1
902 CLAMP, block, end
255045 255045 255045 255045 255045 255045 1
903 HOLDER, fuse terminal, block
255043 255043 255043 255043 255043 255043 2
904 FUSE
255023 255023 255023 255023 255023 255023 2
905 TERMINAL, block
255042 255042 255042 255042 255042 255042 4
906 TERMINAL, end cover
--- --- --- --- --- --- 1
907 BRIDGE, plug in, jumper
255044 255044 255044 255044 255044 255044 2
908 BLOCK, terminal ground
255046 255046 255046 255046 255046 255046 1
909 BREAKER, 1 pole, 50A
255026 255026 255026 255026 255026 255026 1
910 CONTACTOR, relay, 65A
255022 255022 255022 255022 255022 255022 1
911 BREAKER, 2 phase, 40A
247768 247768 247768 247768 247768 247768 1
912 BREAKER, 2 phase, 25A
255050 255050 255050 255050 255050 255050 2
BREAKER, 2 phase, 40A
247768 247768 247768 247768 247768 247768 2
913 BREAKER, 2 phase, 20A
255049 255049 255049 255049 255049 255049 1
914 CONNECTOR, power lug
117679 117679 3
CONNECTOR, power lug
117679 117679 2
915 BAR, power buss, 3 phase
117805 117805 1
BAR, power buss, 1 phase
117678 117678 1
916 CABLE, harness lower
247802 247802 247802 247802 247802 247802 1
917 CABLE, harness upper
247805 247806 247804 247805 247806 247804 1
918 CONNECTOR, 2 pin large
255027 255027 255027 255027 255027 255027 3
919 CONNECTOR, 3 pin
247522 247522 247522 247567 247567 247567 1
920 CONNECTOR, 4 pin
255031 255031 255031 255031 255031 255031 1
922 CABLE, harness
247791†
17H075‡
247791†
17H075‡
247791†
17H075‡
247791 247791 247791 1
Содержание
160- Repair parts
- Contents
- E 30 series
- E 20 series
- E xp1 series
- Models
- Maximum flow rate given for 60 hz operation for 50 hz operation maximum flow rate is 5 6 of 60 hz maximum flow
- Full load amps with all devices operating at maximum capabilities fuse requirements at various flow rates and mix chamber sizes may be less
- E xp2 series
- Total system watts based on maximum hose length for each unit e 20 and e xp1 series 210 ft 64 m maximum heated hose length including whip hose e 30 and e xp2 series 310 ft 94 m maximum heated hose length including whip hose
- Supplied manuals
- Related manuals
- Approvals
- Warnings
- Warning
- Warning
- Warning
- Isocyanate conditions
- Important two component material information
- Keep components a and b separate
- Foam resins with 245 fa blowing agents
- Check with your material manufacturer for chemical compatibility
- Changing the material types used in your equipment requires special attention to avoid equipment damage and downtime
- Changing materials
- Always clean the fluid inlet strainers after flushing
- When changing materials flush the equipment multiple times to ensure it is thoroughly clean
- When changing between epoxies and urethanes or polyureas disassemble and clean all fluid components and change hoses epoxies often have amines on the b hardener side polyureas often have amines on the b resin side
- Notice
- Moisture sensitivity of isocyanates
- Material self ignition
- Temperature control diagnostic codes
- E01 high fluid temperature
- Checks
- Causes of e01 errors
- E02 high zone current
- E06 communication cable unplugged
- E05 circuit board overheated
- E04 fluid temperature sensor fts or thermocouple disconnected
- E03 no zone current
- Motor control diagnostic codes
- Alarms
- Warnings
- Fast e24 errors
- E24 pressure imbalance
- E23 high fluid pressure
- E22 no component b transducer
- E21 no component a transducer
- Causes of fast e24 errors
- Slow e24 errors
- Checks for fast e24 errors
- Causes of slow e24 errors
- E29 brush wear
- E28 high current in motor
- E27 high motor temperature
- E26 low line voltage
- E25 high line voltage
- E31 motor control failure e 30 and e xp2 only
- E99 loss of communication
- E32 motor control overtemperature
- E30 momentary loss of communication
- Communication diagnostic codes
- Troubleshooting
- Reactor electronics
- Primary heaters a and b
- Problems
- Hose heat system
- Repair
- Pressure relief procedure
- Before beginning repair
- Pump removal
- Flushing
- Pump installation
- Install pump b
- Install pump a
- Removal
- Installation
- Drive housing
- Motor brushes
- Brush removal
- Brush installation
- Circuit breaker module
- Capacitor test
- Removal
- Installation
- Electric motor
- Motor control board
- On down
- Transducers
- Electric fan
- Temperature control module
- Test scr circuit
- Replacing temperature control assembly modules
- Line voltage
- Primary heaters
- Heater element
- Thermocouple
- Overtemperature switch
- Heated hose
- Check hose power connectors
- Check fts cables
- Test removal
- Installation
- Fluid temperature sensor fts
- Transformer primary check
- Replace transformer
- Transformer secondary check
- Temperature and pressure displays
- Red stop button
- Display module
- Inlet fluid strainer screen
- Pump lubrication system
- Reactor assembly model e xp1 shown
- Right side of cabinet
- Left side of cabinet
- Detail fluid manifold area detail fluid manifold area
- Detail cabinet area
- See pages 56 through 58 for parts that vary by model
- Parts used on all models
- Use the following tables on this and the next two pages to find parts that vary by model find the reference number and of part in left column and reactor model in top row intersection is correct part number
- See page 55 for parts common to all models
- Parts that vary by model
- Replacement danger and warning labels tags and cards are available at no cost
- Parts that vary by model continued
- Not required for slotted u channel style heater support rails
- Not for sale
- Sub assemblies
- Proportioner module
- Proportioner module parts list
- Fluid heaters
- 6 kw fluid heaters 247507 10 kw fluid heaters
- Part 247509
- Kw single zone fluid heater
- Reactor frame
- Display
- Temperature control
- Motor control
- Fluid manifold
- Circuit breaker modules
- B 400v 3 phase circuit breaker modules e 20 e xp1
- A 230v 3 phase circuit breaker modules e 20 exp 1
- D 230v 3 phase circuit breaker modules e 30 exp 2
- C 230v 1 phase circuit breaker modules e 20 exp 1
- F 230v 1 phase circuit breaker modules e 30 exp 2
- E 400v 3 phase circuit breaker modules e 30 e xp2
- Not for sale
- Circuit breaker modules parts list
- Conversion kit
- Dimensions
- Technical specifications
- All trademarks or registered trademarks are the property of their respective owners
- For the latest information about graco products visit
- For patent information see
- Copyright 2019 graco inc all graco manufacturing locations are registered to iso 9001 www graco com revision zaf november 2019
- Www graco com patents
- Www graco com
- To place an order contact your graco distributor or call to identify the nearest distributor phone 612 623 6921 or toll free 1 800 328 0211 fax 612 378 3505
- Graco standard warranty
- Graco information
- Graco inc and subsidiaries p o box 1441 minneapolis mn 55440 1441 usa
- Graco headquarters minneapolis international offices belgium china japan korea
Похожие устройства
-
Graco REACTOR 2 H-50 PHH156Техническая документация -
Graco REACTOR 2 H-50 PHH156Сертификат -
Graco REACTOR 2 H-50 PHH156Брошюра -
Graco REACTOR 2 H-50 PHH156Инструкция по эксплуатации -
Graco REACTOR 2 H-50 PHH153Техническая документация -
Graco REACTOR 2 H-50 PHH153Сертификат -
Graco REACTOR 2 H-50 PHH153Брошюра -
Graco REACTOR 2 H-50 PHH153Инструкция по эксплуатации -
Graco REACTOR 2 H-50 PHH056Техническая документация -
Graco REACTOR 2 H-50 PHH056Сертификат -
Graco REACTOR 2 H-50 PHH056Брошюра -
Graco REACTOR 2 H-50 PHH056Инструкция по эксплуатации