Graco REACTOR 3 E-30 IHR333 [12/26] Connecting hose bundle sections

Graco REACTOR 3 E-30 CSR332 [12/26] Connecting hose bundle sections
Installation
12 3A7683G
Connecting Hose Bundle
Sections
To connect internally heated hoses and whip hoses to
another hose:
1. Lay the heated hoses end-to-end. Align the fluid
hoses (GH) red to red (component A, ISO) and blue
to blue (component B, RES).
2. Connect the fluid hoses (FH) and tighten the
connections finger tight, then fully tighten the
connections with wrenches.
NOTE: Torque hoses to 3/8 in. (9.5 mm) ID hoses to:
A side to 14 ft-lb (19 N•m).
B side to 20 ft-lb (27 N•m).
NOTE: When connecting the fluid hoses, ensure that
red hoses are connected to red hoses and blue hoses
are connected to blue hoses.
3. Connect the air hoses (AH) and tighten the
connections finger tight, then fully tighten the
connectors with wrenches.
4. Connect electrical wires (EW). Tighten the electrical
connector screws.
NOTE: Torque electrical connector screws to 3-6
in-lb Do not over-tighten the connector screws.
NOTE: When connecting the electrical wires,
ensure that red wires are connected to red wires
and blue wires are connected to blue wires.
5. For hoses with RTD cables: Connect the RTD
cables (RTD) and tighten the connections.
NOTE: RTD Cables are an optional accessory and
only needed when the FTS kit is used.
6. Tape excess electrical wire (EW) to the fluid hoses
(FH). Stagger the electrical connectors as shown to
create the smallest joint bundle possible.
7. Check Hoses for Leaks, page 13.
8. Cover the joint with protective covering. See
Protective Covering, page 14.
ti40421b
FH
FH
FH
FH
AH
AH
EW
EW
ISO
(red)
RES
(blue)
ISO
(red)
RES
(blue)
FH
EW
FH
AH
FH
EW
FH
AH