Graco REACTOR 3 E-30 ISR331 [11/26] Connect hoses to proportioner

Graco REACTOR 3 E-30 26R330 [11/26] Connect hoses to proportioner
Installation
3A7683G 11
Connect Hoses to Proportioner
1. Connect the fluid hoses (FH) to the proportioner
fluid manifold (G). The red fluid hose is for hardener
(component A, ISO), and the blue fluid hose is for
resin (component B, RES).
NOTE: Torque hoses to 3/8 in. (9.5 mm) inner
diameter hoses to:
• A side to 14 ft-lb (19 (N•m)
• B side to 20 ft-lb (27 N•m)
NOTE: Ensure the hose fittings are facing away
from the proportioner.
2. Connect electrical wires (EW). Tighten the electrical
connector screws.
NOTE: Torque the electrical connector screws to
3-6 in-lb. Do not over-tighten the connector
screws.
NOTE: When connecting electrical wires, ensure
that red wires are connected to red wires and blue
wires are connected to blue wires.
3. Connect the air hose (AH).
4. Check that all equipment is properly grounded. See
Grounding, page 10.
NOTICE
Heated hose must always contain fluid when hose
power is on. Never apply power to an empty heated
hose. Powering empty hoses may cause equipment
damage.
NOTICE
Always completely unroll and bleed the air from the
hose before each use. If the air is not bled from the
hose, heat transfer from the heating conductor will
not be uniform. In the worst case, the conductor can
be damage. The warranty is void in such cases.