Graco REACTOR 2 H-50 PHH056 — инструкция по замене защитных устройств и модулей управления [69/110]

Превью страниц Страница 69 / 110
Graco REACTOR 2 H-50 FPH056 [69/110] Replace temperature control module tcm
Repair
Replace Replace
Replace
Surge Surge
Surge
Protector Protector
Protector
1.Loosenconnectionsonterminals1and3on
CB13.SeeElectricalSchematics,page102.
2.Loosenconnectionsoninputtopower
supply(805)onNandLconnections.See
ElectricalSchematics,page102.
3.Removetwoscrews(612),washers(611),and
surgeprotector(705)fromenclosure.
4.Installnewsurgeprotector(705)inreverseorder.
NOTE: NOTE:
NOTE:
Wireonboththecircuitbreakerandpower
supplyareinterchangeable.
Figure10SurgeProtector
Replace Replace
Replace
Temperature Temperature
Temperature
Control Control
Control
Module Module
Module
(TCM) (TCM)
(TCM)
1.PerformShutdown,page48.
2.Opentheelectricalenclosuredoor.
3.DisconnectallconnectorsfromtheTCM(602).
4.Removefournuts(610)andTCM(602).
5.InstallnewTCMmodule(602).Reassemble
partsinreverseorder.
6.Updatesoftwarebyinsertinganupgradetoken
intotheADMandcyclingsystempower.Wait
untiltheupdateiscompletebeforeremovingthe
tokenandrestartingthesystem.
Figure11ReplaceTCM