Calibration Calibration
Calibration
Procedure Procedure
Procedure
NOTICE NOTICE
NOTICE
Topreventdamagetotheheatedhose,ahose
calibrationisrequiredifanyofthefollowing
conditionsaretrue:
Thehosehasneverbeencalibratedbefore.
Asectionofhosehasbeenreplaced.
Asectionofhosehasbeenadded.
Asectionofhosehasbeenremoved.
NOTE: NOTE:
NOTE:
TheReactorandheatedhosemustbeatthe
sameambienttemperaturetogetthemostaccurate
calibration.
1.EnterSetupModeandnavigatetoSystem
screen3,thenpresstheCalibratesoftkey
.
2.PresstheContinuesoftkeytoacknowledge
theremindertohavethehoseatambient
conditions.
3.Waitwhilethesystemmeasuresthehose
resistance.
NOTE: NOTE:
NOTE:
Ifhoseheatwasonpriortothecalibration
procedure,thesystemwillwaitupto󰘰veminutes
toallowthewiretemperaturetoequalize.
NOTE: NOTE:
NOTE:
Thehosetemperaturemustbeabove32
°F(0°C)duringcalibration.
334946H 65