Comprag FR1510-500 [31/120] Error description

Comprag F0710 [31/120] Error description
31COMPRAG Screw air compressor A/F-Series
GREASE M1 SET
Lubricate motor bearings. Set maintenance interval
4000h
Set value
BELT CHANGE SET
Change belts. Set change interval
4000h
Set value
LANGUAGE SELECT
Language EN/DE
ENGLISH
Set value
USER PASSWORD
User password
****
No access to parameter
If there is no activity for 60 seconds in the current menu, the control will automatically return to the
main menu.
Factory param
For servicing mode (view with password). Modication only possible by manufacturer.
ADJUST. param
Basic settings and maintenance hour counter (view and change with password).
4.2 Error description
Alarm (warning): The indicator ashes and the machine continues to run.
Error: The indicator is permanently lit, there is an accompanying acoustic signal and the machine
switches off. The error message can be acknowledged after the cause of the error has been resolved.
In order to acknowledge the error message, press and hold the ‘back to main menu’ button.
Restarting operation without eliminating the cause of the fault
isnot permitted!
Alarm (warning, compressor continues to run)
ALARM:
Oil/air mixture temperature at the compressor outlet high
TEMP HIGH 105°C
ALARM: 0110h
Maintenance interval exceeded
OIL FILTER SOON