Comprag А5508 [14/92] Requirements on installation facility

Comprag А3010 [14/92] Requirements on installation facility
14
Version 5.2
Model
Compressor dimensions Packaging dimensions
Length
L, mm
Width
D, mm
Height
H,mm
Weight,
kg
Length
L, mm
Width
D, mm
Height
H,mm
Weight,
kg
А30
1400 1000 1500
705
1600 1100 1750
777
А37 745 830
А45
1650 1100 1730
950
1850 1200 1860
1165
А55 1150 1194
3.3
Requirements on installation facility
Fig. 3.3
Installation
facility proposal A30 – A55.
1. Air inflow
2. Air outflow
Ensure that the oor of the facility can withstand the weight of the compressor. Install the
compressor on a level surface that is able to bear its weight.
Adjust the horizontal axis of the compressor using a levelling instrument.
If the compressor is not anchored to the base on which it is installed, the tilt angle with
respect to the horizontal surface must not exceed 3°.
If the compressor is anchored to the base on which it is installed, the tilt angle with respect
to the horizontal surface must not exceed 7°.
Install the compressor in a facility where precipitation cannot reach.
1500
1500
1500
1500
1500
2
1

Содержание

Скачать