COMPRAG Screw air compressor A-Series
Choose a facility for installing the compressor with a minimum level of dust. Install the com-
pressor at least 1,5 m from walls.
If multiple compressors are installed, there should be a 1,5 m minimum distance between
each compressor.
There should be a 4 m safety distance from the area of the operated equipment connected
to the compressor.
The facility in which the compressor is installed must be tted with a combined extract-and-
in
-
put ventilation system.
The facility where the compressor is installed should be provided
with air inow equivalent to twice the compressor’s capacity.
3.4 Connection to the compressed airline
Provide the throughput capacity of the compressed-air line in accordance with the perfor-
mance of the compressor.
In order to avoid damage associated with seal failure of the compressed-air line, the com-
pressor should be connected via a exible hose.
All components of the compressed-air line must have a working pressure no less than the
compressor’s nominal pressure.
Use a pressure vessel with a capacity corresponding to the compressor’s performance and
the compressed air consumer.
3.5 Connecting to power supply
The compressor is not supplied with a power cable.
The cable size must be chosen to ensure that the maximum voltage drop not exceed 5 % of
the nominal voltage value. Cable length must not exceed 25 m. Ambient temperature in the
facility must not exceed 40°C.
The cable must be sheathed with a re retardant compound.
An isolating switch must be tted within reach of the compressor to facilitate connection
and maintenance.
The compressor must be earthed and protected against short
cir- cuits in each phase, impermissible voltage uctuation and
phase failure.
The power cable has to be fed into the compressor.