Comprag D-1110 [12/92] Start up

Comprag D-1508 [12/92] Start up
12
Version 1.4
Main components
К1---К4 Contactor YA Solenoid valve
М1, М2 Electric motor QS Automatic power switch
Т Temperature sensor CT1, CT2 Current Transformer
I/P Pressure sensor R,C RC elements
SB Emergency stop Tr Transformer
F1, F2 Fuses i-LOG Controller
2.7 General description
Voltage (V) Frequency (Hz) D11.. D15.. D18.. D22..
Мaterial - copper. Cable size (mm²)
380 / 400 50 6 10 10 16
Fuse value (A)
380 / 400 50 25 32 40 50
3. Start up
3.1 Lifting and carrying
All lifting should be carried out using a forklift truck with a carrying ca-
pacity suited to the compressor. Lifting may be carried out with loading
cranes, winches and other machinery, using a crossbeam with the
right length. Local safety guidelines for lifting have to be observed.
AD
C
G
B
For transport with a forklift
truck, use the rigging holes
in the frame. The compressor
has slotted rigging holes with
width C g. 3.1. Move the
compressor carefully.
Fig. 3.1 Lifting and carrying
D11 – D22