Comprag MEX-E-1 [19/84] Storage

Comprag MEX-E-2 [19/84] Storage
19
CONTRACOR
®
MEX Сondensate removal system
Fan blades rotate
slowly.
Safety fuse has blown or short
circuit.
Check the fuse.
Power unit is defective. Check the power unit or cable con-
nections, replacing them if necessary.
Damaged components. Inspect fan blades for damage. Replace
faulty components.
Electric motor is defective. Check free rotation of fan blades.
If electric motor does not rotate the fan,
the electric motor will have to be serviced
or replaced.
Cyclone separator
doesn’t drain
condensate.
Damaged components. Inspect the condensate drain valve for
damage. Replace faulty components.
Clogging. Remove foreign objects from drain valve.
Cooler does not turn
on after pressing the
Start button.
One or several phases are
absent in the electric power
supply.
Check the mains power supply and
rectify the fault.
The phase sequence in the
electric power supply has been
upset.
Change the phase sequence in the
electric power supply.
7. Storage
The system should be stored at a temperature between +5º and +40ºС with max. 85%
relative humidity.