EKUHWBB + EKUHW2WB + EKHWSU150-300B3V3
Domestic hot water tank with option kit for air to water heat pump
system
4P344370-1 – 2013.03
Contents Page
Introduction ....................................................................................... 1
General information.................................................................................. 1
Scope of this manual................................................................................ 1
Model identification .................................................................................. 1
Accessories....................................................................................... 1
Accessories supplied with the EKHWSU domestic hot water tank .......... 1
Accessories supplied with the EKUHWBB option kit for the
domestic hot water tank ........................................................................... 2
Accessories supplied with the EKUHW2WB option kit for the
domestic hot water tank when the EKSOLHWAV1 option kit is
installed .................................................................................................... 2
Optional equipment .................................................................................. 2
Installation of the EKHWSU domestic hot water tank ....................... 2
Main components..................................................................................... 3
Outlook diagram....................................................................................... 4
Installation guidelines............................................................................... 4
Installing the domestic hot water tank ...................................................... 4
Connecting the water circuits ................................................................... 4
Field wiring ............................................................................................... 6
Installation of the option kit on the domestic hot water tank.............. 9
Piping requirements ................................................................................. 9
Installation procedure of the option kit.................................................... 10
Commissioning................................................................................ 10
Filling up................................................................................................. 10
Draining .................................................................................................. 10
Maintenance.....................................................................................11
Troubleshooting................................................................................11
General guidelines ..................................................................................11
General symptoms ..................................................................................11
Technical specifications................................................................... 12
Domestic hot water tank specifications .................................................. 12
Pressure reducing valve specifications .................................................. 13
Field wiring diagram ............................................................................... 13
Introduction
General information
Thank you for purchasing this Daikin Altherma EKHWSU domestic
hot water tank.
The Daikin Altherma domestic hot water tank must be installed by a
competent person and be installed in compliance with instructions as
of subject in this manual, all current legislation, codes of practice and
regulations governing the installation of unvented hot water cylinders
in force at the date of installation.
This installation is subject to building regulation approval,
notify Local Authority of intention to install.
The domestic hot water tank is to be connected to the Daikin
Altherma unit.
The EKHWSU domestic hot water tank with integrated 3 kW
electrical booster heater is available in three types: 150, 200 and 300.
All models can be floor mounted, while the 150 type model can be
wall mounted as well via option kit EKWBSWW150.
Scope of this manual
This installation manual describes the procedures for installing and
connecting the EKHWSU domestic hot water tanks with the
EKUHWBB option kit and with the EKUHW2WB option kit in case the
EKSOLHWAV1 option kit is to be installed as well.
Model identification
Domestic hot water tank
Accessories
Accessories supplied with the EKHWSU domestic hot
water tank
1 Thermistor + connection wire (12 m)
2 Contactor - fuse assembly
3 Contactor fixing screw
4 Tapping screw
5 3-way valve + motor
6 Installation manual
EKHWSU150B3V3 EKUHWBB
EKHWSU200B3V3
EKHWSU300B3V3 EKUHW2WB
Domestic hot water tank with option kit for air to
water heat pump system
Installation manual
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.
PLEASE LEAVE THIS MANUAL WITH THE EKHWSU
DOMESTIC HOT WATER TANK AFTER INSTALLATION.
IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.
THE UNIT DESCRIBED IN THIS MANUAL IS DESIGNED
FOR INDOOR INSTALLATION ONLY AND FOR
AMBIENT TEMPERATURES RANGING 0°C~35°C.
EK HWS U 150 B 3 V3
Booster heater voltage
V3=1P, 230 V
Capacity booster heater: 3 kW
Series
Indication of storage capacity in litres
Special version for United Kingdom only
Standard version when no letter is mentioned
Hot Water stainless Steel tank
European Kit
1x 2x 1x1x
1x
4x
1356
2
4
4P344370-1.book Page 1 Tuesday, April 2, 2013 2:32 PM
Содержание
- Domestic hot water tank with option kit for air to water heat pump system 1
- Installation manual 1
- Accessories 2
- Accessories supplied with the ekhwsu domestic hot water tank 2
- Contents 2
- General information 2
- Installation manual 2
- Introduction 2
- Model identification 2
- Scope of this manual 2
- Accessories supplied with the ekuhw2wb option kit for the domestic hot water tank when the eksolhwav1 option kit is installed 3
- Accessories supplied with the ekuhwbb option kit for the domestic hot water tank 3
- Installation of the ekhwsu domestic hot water tank 3
- Optional equipment 3
- C and excessive water pressure 10 bar in the domestic hot water tank 4
- Do not install heaters without thermal cut outs 4
- Expansion relief valve option kit the pressure relief valve prevents excessive water pressure 8 bar in the water circuit 4
- For ekuhw2wb only secondary thermal protector solenoid 2 way valve the thermal protector will close the solenoid 2 way valve setting 85 c both thermal protectors are activated when the temperature becomes too high when activated the protectors have to be reset on the domestic hot water tank by pressing the red button for access remove the electrical box lid 4
- For ekuhw2wb only thermostat solenoid 2 way valve the thermostat will close the solenoid 2 way valve when the temperature becomes too high setting 79 c 4
- Main components 4
- Notice 4
- Refer to installation of the option kit on the domestic hot water tank on page 9 for connection of other safety devices in accordance with relevant local and national regulations 4
- Safety devices 4
- Switch off the power supply before opening the electrical box lid 4
- The domestic hot tank relief valve connections should not be used for other purposes 4
- The electrical box lid must only be opened by a licensed electrician 4
- Thermal protector the booster heater in the domestic hot water tank is equipped with a thermal protector setting 85 c 4
- Connecting the 3 way valve 5
- Connecting the water circuits 5
- Installation guidelines 5
- Installing the domestic hot water tank 5
- Outlook diagram 5
- Field wiring 7
- Power circuit and cable requirements 7
- Procedure 7
- Thermistor cable 7
- For e d b h l q011 014 016 units only 8
- For ekhbh x units only 8
- Note only relevant field wiring is shown 8
- For ekcbh x units only for ehbh x units only 9
- X2m 8 9 10 a1p x9a x2m 13 14 9
- Fixed grating 10
- Installation of the option kit on the domestic hot water tank 10
- Piping requirements 10
- Trapped effluent water 10
- After completing the installation 11
- Commissioning 11
- Discharge 11
- Draining 11
- Filling up 11
- Installation procedure of the option kit 11
- Only when installing the ekuhw2wb option kit flow inlet connection 11
- Pre assembly 11
- Water main in 11
- General guidelines 12
- General symptoms 12
- Maintenance 12
- Troubleshooting 12
- Domestic hot water tank specifications 13
- Symptom 4 continuous water discharge 13
- Technical specifications 13
- 14 1 2 x4m x2m k3m 14
- Field wiring diagram 14
- Pressure reducing valve specifications 14
Похожие устройства
- Daikin EKMBDXA Инструкция по монтажу
- Daikin EKRTR Приложение к руководству для дополнительного оборудования
- Daikin EKRTW Приложение к руководству для дополнительного оборудования
- Daikin EKSH-P Руководство по эксплуатации
- Daikin EKSOLHW Приложение к руководству для дополнительного оборудования
- Daikin EKSV-P Руководство по эксплуатации
- Daikin EMRQ-A Инструкция по монтажу
- Daikin ERAD-E-SL Инструкция по эксплуатации
- Daikin ERAD-E-SS Инструкция по эксплуатации
- Daikin ERHQ-BV3 Инструкция по монтажу
- Daikin ERHQ-BW1 Инструкция по монтажу
- Daikin ERLQ-CV3 Руководство по эксплуатации
- Daikin ERLQ-CW1 Инструкция по монтажу
- Daikin EWAD-E-SL Инструкция по эксплуатации
- Daikin EWAD-E-SS Инструкция по эксплуатации
- Daikin EWAD-TZPLB Руководство по эксплуатации
- Daikin EWAD-TZPRB Руководство по эксплуатации
- Daikin EWAD-TZPSB Руководство по эксплуатации
- Daikin EWAD-TZSLB Руководство по эксплуатации
- Daikin EWAD-TZSRB Руководство по эксплуатации