Timberk AC TIM 07C P6 [6/20] Operating modes
![Timberk AC TIM 07C P6 [6/20] Operating modes](/views2/1936339/page6/bg6.png)
www.timberk.com • Electric air conditioner
6
CONTROL PANEL & DESCRIPTION OF FUNCTION
7. OPERATING MODES
NOTICE:
Never turn the air conditioner off by unplugging
from the mains. Always press the button 1,
then wait for a few minutes before unplugging.
This allows the appliance to perform a cycle of
checks to verify operation.
1. Power button. Press this button to switch on or off the unit
2. Light of high cooling. The appliance will work in cooling mode with
high fan speed.
3. Light of low cooling. The appliance will work in cooling mode with
low fan speed.
4. Light of alarm
5. Light of low fan speed. The appliance will work in low fan speed.
6. Light of high fan speed. The appliance will work in high fan speed.
ATTENTION!
The unit can evaporate condensed water and
automatically drain it through the hose*.
When the unit is in cooling mode, it is not necessary
to install the condensate drainage pipe since
condensate evaporates automatically. Make sure
that when the unit is operating, the rubber plug of
the drainage hose is securely fixed.
Disconnect the air outlet hose, connect the
drainage hose to the drainage hole and drain water
from the unit to ensure maximum dehumidification
efficiency.
When drain hose not attached water collects in the
tank for condensate. When the tank is filled on the
LCD display shows the E4.
To resume the operation, remove the rubber plug of
the drainage hose to drain water at first. After water
is drained…
1
2
3
4
5
6
Содержание
- Instruction manual руководство по эксплуатации 1
- Модели models 1
- Contents 2
- Dear customer 2
- Important information 2
- Important 3
- Precautions 3
- Air outlet grille 2 control panel 3 castors 4 intake grille 5 remote control receiver 6 filter 7 handles 8 air exhaust hose housing 9 condensate drain 10 power cable 11 flange cap 12 air exhaust hose 13 hose outlet 14 hose inlet 15 castor locks 16 suckers 17 window bracket 18 drain pan 19 drain hose the accessary is optional not in the set 4
- Device description 4
- Notice 4
- Technical characteristics 4
- The manufacturer reserves the right to make changes in the design scope of delivery product manufacturing technology as well as change its technical characteristics to improve its consumer and technical properties without prior notice 4
- Appliance control 5
- Delivery set 5
- Attention 6
- Notice 6
- Operating modes 6
- Attention 7
- Maintenance 7
- Troubleshooting 7
- Date of the conditioner manufacture is shown in a serial number of the device for more details please ask a shop assistant 8
- Error codes for lcd display models 8
- From 15 to 85 8
- From 30 to 50 8
- Humidity requirements 8
- Not included 8
- Service life 8
- Service life of the appliance is 10 years provided that the respective installation and operation rules are observed 8
- Temperature requirements 8
- This product must have storage in dry well ventilated space of warehouse at the temperature not lower than 30 8
- Transportation and storage 8
- Upon expiration of the service life the appliance should be utilized in accordance with norms regulations and procedures effective in the place of utilization 8
- Utilization rules 8
- We are exploring new technologies and we constantly improving the quality of our products that s why specifications design and accessories are subject to change without any specific notice 8
- Www timberk com electric air conditioner 8
- Важная информация 9
- Важная информация 1 2 меры предосторожности 2 3 технические характеристики 3 4 описание прибора 4 5 комплект поставки 4 6 управление прибором 4 7 режимы работы 5 8 обслуживание 8 9
- Примечание 9
- Содержание 9
- Уважаемый покупатель 9
- Меры предосторожности 10
- Примечание 10
- Воздуховыпускная решетка 2 панель управления 3 колеса 4 воздухозаборная решетка 5 приемник пульта дистанционного управления не используется в данной серии 11
- Изготовитель оставляет за собой право без пред варительного уведомления покупателей вносить изменения в конструкцию комплектацию техно логию изготовления изделия а также менять его технические характеристики с целью улучшения его потребительских и технических свойств 11
- Модель 11
- Описание прибора 11
- Примечание 11
- Рис 3 11
- Технические характеристики 11
- Комплект поставки 12
- Управление прибором 12
- Примечание 13
- Режимы работы 13
- Внимание 14
- Обслуживние 14
- Примечание 14
- Www btpart ru 16
- Все расходные материалы для продукции timberk вы можете приобрести на сайте www btpart ru 16
Похожие устройства
- Timberk AC TIM 07H P2 Руководство по эксплуатации
- Timberk AC TIM 07H P3 Руководство по эксплуатации
- Timberk AC TIM 07H P4 Руководство по эксплуатации
- Timberk AC TIM 07H S10(B) Руководство по эксплуатации
- Timberk AC TIM 07H S11 Руководство по эксплуатации
- Timberk AC TIM 07H S2 Руководство по эксплуатации
- Timberk AC TIM 07H S4 Руководство по эксплуатации
- Timberk AC TIM 07H S8 Руководство по эксплуатации
- Timberk AC TIM 07H S9 Руководство по эксплуатации
- Timberk AC TIM 09H P2 Руководство по эксплуатации
- Timberk AC TIM 09H P5R(BU) Руководство по эксплуатации
- Timberk AC TIM 09H S10(B) Руководство по эксплуатации
- Timberk AC TIM 09H S11 Руководство по эксплуатации
- Timberk AC TIM 09H S2 Руководство по эксплуатации
- Timberk AC TIM 09H S4 Руководство по эксплуатации
- Timberk AC TIM 09H S8 Руководство по эксплуатации
- Timberk AC TIM 09H S9 Руководство по эксплуатации
- Timberk AC TIM 09HDN S11 Руководство по эксплуатации
- Timberk AC TIM 09HDN S5 Руководство по эксплуатации
- Timberk AC TIM 09HDN S8R Руководство по эксплуатации