FIRST Austria FA-2460-4-BA [3/6] English

FIRST Austria FA-2460-4-BA [3/6] English
4 5
ENGLISH
ENGLISH
Temperature trend display
After you insert the batteries, the weather station
measures the current temperature. The trend
display shows a neutral temperature course
(horizontalarrow).
The further course of the trend display is
determined as follows:
If, after an hour, the temperature is more than
1°Chigherthanthevaluemeasuredrst,
thenapositivecourseisdisplayed(arrow
pointingupwards).
If, after an hour, the temperature is more than
1°Clowerthanthevaluemeasuredrst,then
anegativecourseisdisplayed(arrowpointing
downwards).
If the temperature does not change within an
hour, then the upward or downward pointing
arrow becomes a horizontal arrow. The
measured temperature is then taken as the
neutralvaluefromwhichfurtherprognoses
are made.
Maximum/Minimum Temperature/Relative
Humidity
To toggle indoor/outdoor maximum, minimum
temperature and humidity data, press the
“MEM” button:
Once to show the maximum temperature and
humidityvalues.
Twice to sow the minimum temperature and
humidityvalues
Three times to return to the current
temperatureandhumiditylevels
To reset the maximum and minimum
temperature and humidity, press and hold
down the “MEM” button about 2 seconds.
This will reset all minimum and maximum
datarecordedtothecurrentdisplayedvalues.
F.Y.I.:
If the temperature reading is below ranges,
the LL.L will be displayed. If the temperature
readingisaboveranges,theHH.Hwillbe
displayed.
Relative air pressure trend display
After you insert the batteries, the weather station
measuresthecurrentrelativeairpressure.
Thetrenddisplayshowsaneutralrelativeair
pressurecourse(horizontalarrow).
The further course of the trend display is
determined as follows:
• If,afteranhour,therelativeairpressure
ismorethan2hPahigherthanthevalue
measuredrst,thenapositivecourseis
displayed(arrowpointingupwards).
• If,afteranhour,therelativeairpressure
ismorethan2hPalowerthanthevalue
measuredrst,thenanegativecourseis
displayed(arrowpointingdownwards).
• Iftherelativeairpressuredoesnotchange
within an hour, then the upward or downward
pointing arrow becomes a horizontal arrow.
Themeasuredrelativeairpressureisthen
takenastheneutralvalueformwhichfurther
prognoses made.
Temperature alert setting
Press and hold down the ”ALERT” button for
2 seconds until the icon for the Temperature
Alert”startstoash
The icon of Upper limit of the Temperature
alarmstartstoash.Usethe“UP”and
“DOWN” buttons to set the required
maximum temperature. Press ”ALERT” to
conrmyoursetting.
The icon of the Lower limit of the Temperature
alarmstartstoash.Usethe“UP”and
“DOWN” buttons to set the required minimum
temperature. Press ”ALERT” button to
conrmyoursettingandtoendthesetting
procedure
When Temperature Alert is On alert : the
temperaturealarmstartstoash.thereare
3 beep sounds per second, the alarm will
soundfor1minutesifyoudonotdeactivateit
by pressing any button.
• Activateanddeactivatingthetemperature
Alert:Brieypress”ALERT”buttontoactivate
ordeactivatethetemperaturealert.
Radio connection to outdoor sensor:
Insert the 2 batteries in to the transmitter. Pay
attentiontoobservethecorrectpolarity.One
sensorissupliedwithyourreceiver.Bydefault,
thissensoristhechannel1,Selectthechannel
2 or 3 thanks to the “CH” knobs at the back of
the sensor.
• Pressthe“CH”buttontoselectachannel(1
to3).Thisgivesyoutheoptionofpolling3
outdoorsensorswith1weatherstation.
Press and hold down the “CH” button for 2
secondstosearchforoutdoorsensors(to
erasethecurrentdatainsidetheRCclock).
Relative air pressure history
Therelativeairpressurehistorycanbedisplayed
numericallytovietheairpressurechangesover
thelast0-12hours.
Press the “SET/HISTORY” button to display
the recorded air pressure changes during the
last0-12fullhours.Thenumericrecordedair
pressure will be display according to the hour.
Weather forecast
The weather stations use the air pressure
dataofthelasttwelvehourstocreatea
weatherforecastforthenext12to24hours.
If must be taken into account that the data
withinthersttwelvehoursafterinsertingthe
batteries will not be correct, as the weather
stationhastogetusedtotheenvironmental
circumstances after the restart.
• Theforecastcanbegivenforaradiusofup
to12-20km.
When forecasting the weather, the station
uses5icons:sunny,lightcloudcover,cloudy,
rain and stormy.
• Iftemperaturerecordedfallsbetween4°C
(39.2°F),LCDdisplaythe“
“ indicator. it will
stop display once the temperature is out of
this range.
Please see table
Set channel
Press “CH” button to toggle between the
outdoortransmitters1,2and3(ifmorethanone
transmitterisused).
The moon phase and tide indicator
The Moon icon and tide indicator of the Weather
Stationwillalsodisplay8differentMoonphase
and 3 kinds of tide phases according to the set
calendar.
Backlight:
Brieytouchthe“SNOOZE/LIGHT”toactivate
the display lighting for 5 seconds.
Storage
Itisrecommendedtostoreinacoveredanddry
place at an ambient temperature not higher than
+40°Cwithrelativehumidityabove70%andthe
absenceintheenvironmentofdust,acidand
othervapours.
Transportation
Tothedevicespecialtransportationrulesare
not applied. When transporting the unit, use the
originalpackaging.Duringtransportation,avoid
drops,impactsandothermechanicalinuences
onthedevice,aswellasdirectexposureto
atmosphericprecipitationandaggressive
environments.
Unit operating life is 3 years
Environment friendly disposal
Youcanhelpprotecttheenvironment!
Please remember to respect the local
regulations: hand in the non-working
electrical equipments to an appropriate waste
disposal center.
SAFTEY GUARDS
Before using the appliance, read this instruction
manualcarefullyandsaveitforuseasa
reference material.
Usethedeviceonlyforitsintendedpurpose,as
described in this manual. Incorrect handling of
thedevicecanleadtoitsfailure,causingharmto
the user or his property.
Do not subject the unit to shock, dust or
moisture.
Do not allow liquid or foreign objects to enter
the cabinet
• Donotplacethedevicenearsourcesofheat,
exposed to direct sunlight
• Installtheunitonaat,stablesurfacein
placeswithadequateventilation.Donotblock
anyventilationopenings.
• Donotrepairthedeviceyourself,contactan
authorizedservicecenter
• Thisdeviceisnotintendedforusebychildren
or persons with disabilities
If there is a DC power adapter, DC:
Check the integrity of the power cord and
plug for connection
Only plug the power adapter into a 220V
network
Do not touch the cord, plug, adapter housing
with wet or wet hands
Weather forecast (table)
lightly cloudy sunny cloudy rainy rainstorm
Скачать
Случайные обсуждения