WMF 9000 F 03.8900.0020 [15/88] Installation location

WMF 9000 F 03.8900.0010 [15/88] Installation location
15
User Manual WMF 9000 FGV
Safety
Installation location
The machine must be set up so as to allow good visual access.
The device must be placed and leveled on ahorizontal, sturdy,
water-resistant, and heatproof base.
The device must not be cleaned using awater jet. The device
must be installed where it is protected against water spray.
The device must not be located on asurface that is sprayed or
cleaned with awater hose, steam jets, steam cleaner, or similar
devices.
Water supply
On site:
½" (TW12) with main shutoff valve and dirt filter (250µm)
Min. 0.36MPa (3.6bar) flow pressure at 6l/min
(1
maximum inlet temperature 35°C.
Machine:
Boiler feed ½" (TW12)
Rinsing line ⅜" (TW8)
The set of hoses provided with the new coffee machine and/or
the new water filter must be used. Do not use the old set
ofhoses.
(1
This takes the normal pressure losses via water supply set and water
filter into account. As aresult, the flow pressure of 0.2MPa (2bar)
at6l/min required by the machine for maximum hourly output
willbeensured.