Aten VK1200 [7/10] Acknowledge

Aten VK2100A [7/10] Acknowledge
7
Relay
Usage:
Control and configure relay ports.
Syntax:
relay [p sequence] [tpulse duration] [control] [help] ↙
Keyword:
p : port
tpulse : closed period for pulse
help: show instructions
Parameter:
sequence : port, separated by comma for multiple ports
* (all ports)
duration : time period in millisecond.
control : open - turn off
close - turn on
pulse - close the relay channel then open
toggle - relay toggle
read - display status
Acknowledge:
Command OK↙ : Command is correct and the function is executed.
Command incorrect↙ : Command and/or parameters are incorrect and not executed.
Example:
relay help ↙ : show instructions
relay p01 close ↙ : close port1 channel.
relay p01 open ↙ : open port1 channel.
relay p01,04,07 close ↙ : close port 1, 4, 7 relay channels.
relay p02 tpulse 500 pulse ↙ : close port2 500ms then open.
relay p02 read ↙ : display port2 status.