Aten VE8952R [81/122] Switching sources

Aten VE8952R [81/122] Switching sources
Chapter 6. CLI Commands
69
Switching Sources
To switch source on a display, type the command in this format:
sw + i<port> + o<port> + on | off + \r\n
Examples
To switch the source to a VE8900 transmitter with the IP address of
10.0.90.11 to the VE8900 receiver you used to make the CLI connection,
type sw i10.0.90.11 on
To switch the source to a VE8950 transmitter with the ID of 1 on a
VE8950 receiver with the ID of 5, type sw i1 o5 on
To stop source transmission from a VE8900 transmitter with the IP
address of 10.0.70.43 to a VE8900 receiver with the ID of 3, type
sw i10.0.70.43 o3 off
Control Description
i<port> Indicates the device ID, MAC ID, or the IP address of the input source
(VE8900 / VE8950 / VE8952 transmitter) device.
o<port> Indicates the device ID, MAC ID, or the IP address of the output
(VE8900 / VE8950 / VE8952 receiver) device. Omit this variable to
assign the specified source to the display that you used to make the
CLI connection.
on Enables the specified command.
off Disconnects from the current connection.
\r\n Ends the command.

Содержание