Luxstahl MARCO Ecosmart PB10 Руководство по эксплуатации онлайн [2/13] 764021
![Luxstahl MARCO Ecosmart PB10 Руководство по эксплуатации онлайн [2/13] 764021](/views2/1995736/page2/bg2.png)
1900051 REV.3 Page 2 of 13
SAFETY:
This appliance must be earthed.
Risk of flooding. A hose is not supplied with this unit. When connecting to the water mains it
should be considered that a hose is not a permanent connection. It is, therefore, advisable to
switch off boiler and close the stopcock valve when boiler is not in use, e.g. overnight,
weekends etc.
Risk of scalding. Beware of accidentally operating the water drawoff tap or push button
especially when cleaning the front of the boiler.
The utmost care has been taken in the manufacture and testing of this unit. Failure to install,
maintain and / or operate this boiler according to the manufacturer’s instructions may result in
conditions that can cause injury or damage to property. If in any doubt about the serviceability
of the boiler always contact the manufacturer or your own supplier for advice.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory, or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the appliance.
In the event any wires are damaged, such wires can only be replaced by experts or
professional after service staff from the manufacturer, after service department or similar
function departments.
INSTALLATION DETAILS:
Electrical installation:
Electrical specification:
Machine type
Rated power
Plug type
Plumbing
1000677US
1000678US
2.9kW @ 240V
2.2kW @ 208V
50Hz / 60Hz
NEMA 6-15P or
NEMA L6-20P
(3/8" NPT)
1000677
1000678
2.8kW @ 230V
50Hz / 60Hz
BS 1363
(3/4" BSP)
1000677MJ
1000678MJ
2.8kW @ 200V
50Hz / 60Hz
-
(3/4" BSP)
Plumbing installation procedure:
Mains water pressure required (limits): 5-50psi (35-345kPa).
Fit a stop Valve on a cold water line and attach a suitable fitting.
Connect a suitable hose to the stop valve fitting.
Turn on the water to flush any impurities, dust etc from the inlet hose and water pipe. Allow
several gallons through. Especially for new installations.
Connect the hose to the inlet valve of the boiler. Make sure a sealing washer is fitted.
Turn on water and check for leaks.
Backflow Prevention:
This equipment must be installed with adequate backflow protection to comply with all
applicable federal, state and local codes. US versions only.
Operating boiler for the first time:
Check that all installation procedures have been carried out.
Ensure water valve is on.
Plug boiler into suitable socket.
Содержание
Похожие устройства
- Lofra DOLCEVITA 900 RR Руководство по эксплуатации
- Lofra DOLCEVITA 900 NM Руководство по эксплуатации
- Lofra DOLCEVITA 900 IN Руководство по эксплуатации
- Lofra DOLCEVITA 900 BI Руководство по эксплуатации
- Liebherr SK 4240 Руководство по эксплуатации
- Liebherr GN 4615 Руководство по эксплуатации
- Liebherr GT 2122-21 Руководство по эксплуатации
- Liebherr CNPel 4813-22 Руководство по эксплуатации
- Liebherr GTP 4656-22 Руководство по эксплуатации
- Lumme LU-3831 WP Руководство по эксплуатации
- Luxstahl MARCO Jet 6 Twin Руководство по эксплуатации
- Lex RFS 202 DF WH Руководство по эксплуатации
- Lelit Mara PL62T Руководство по эксплуатации
- Kuppersberg NSFT 195902 X Руководство по эксплуатации
- KRAFT BDW335BLG Руководство по эксплуатации
- KRAFT BDW280QX Руководство по эксплуатации
- KRAFT BDW200BL Руководство по эксплуатации
- KRAFT BCW50 Руководство по эксплуатации
- KRAFT BDW225BLG Руководство по эксплуатации
- Kuppersberg Noff 19565 X Руководство по эксплуатации