Electric convector
EN
SMT mode
Press button, symbol lights, Set required temperature and compared it with room
temperature, if setting temperature and room temperature dierence is 5 degrees or over 5
degrees, the product works with high power (2000W), if setting temperature and room tempera-
ture dierence is over 3 degrees but not more than 5 degrees, the product works with middle
power (1200W), if setting temperature and room temperature dierence is less 3 degrees, the
product works with low power (800W), if setting temperature is higher than room temperature,
the product stops heating.
Power adjustment
Low power lights, o;
Middle power, lights, o;
High power, both on.
Protection function
Sensor problem protection: Sensor o or other problem, LED shows E1, heating element stops
heating output Tip-over protection: the products tip-over 45 degrees, it stops working, ash-
es, and the product would be under standby status.
Over-heating protection: once the whole product is overheating, thermal limiter works, the prod-
uct would be power o, LED o.
Operation voice
When valid operate any button once, buzzer ring once, aer connection of power, buzzer ring
once.
Screen fade out Function
If no pressing of « » button together, all the symbols on LED would be on status.
Press « » button together, shows status of the product, other symbols o, press
any button to show working status.
Mandatory power functions
Within 2 minutes aer power on of the product for the rst time, SMART mode and temperature
setting function invalid, the whole product works under setting power for PCB checking of pro-
duction line.
Memory function
Thermo-limiter o and rework, tip-over switch rework and accidently electricity o, the product
will memory working status of last time.