Faber IN-LIGHT EV8P WH MATT A52 [5/140] Controls

Faber IN-LIGHT EV8P WH MATT A52 [5/140] Controls
5
Controls
S1
L T1 T2 T3 T4
Button Function Led
L Turns the lights ON/OFF at maximum strength. -
Press and hold for approx. 2 seconds to turn the lighting system on and
off at reduced intensity.
-
T1 Turns the motor on/off at speed one. Fixed
Delay Function:
Press and hold the button for approx. 3 seconds to Activate/Deactivate the
Delay function (automatic switching off of the Motor, the Fans and the Lighting
with a 30’ delay).
Cannot be enabled when Intensive or 24H are on.
Flashing
T2 Turns the Motor on at speed two. Fixed
Press and hold the button for approximately 5 seconds, with all the loads
turned off (Motor and Lights), to turn the Activated Charcoal Filter alarm on.
7KH UHOHYDQW /(' ÀDVKHV WZLFH WR FRQ¿UP
To turn the alarm off, press the button again and hold for at least 5 seconds.
7KH UHOHYDQW /(' ÀDVKHV RQFH
Flashing
T3 Turns the Motor on at speed three. Fixed
Press and hold the button for approximately 3 seconds, with all the loads
turned off (Motor and Lights), to reset the Filter saturation alarm. The
LED S1 ÀDVKHV WKUHH WLPHV
-
T4 Turns the Motor on at INTENSIVE. Fixed
This speed is timed to run for 6 minutes. At the end of this time, the
system returns automatically to the speed that was set before. If it is
activated with the motor turned off, the hood will switch to OFF at the
end of the time.
Press and hold for 5 seconds to enable the remote control, indicated by
WKH /(' ÀDVKLQJ WZLFH
Press and hold for 5 seconds to disable the remote control, indicated by
WKH /(' ÀDVKLQJ MXVW RQFH
-
S1 Signals the Metal Grease Filter saturation alarm, indicating that it is
QHFHVVDU\WRZDVKWKH¿OWHUV7KH DODUPLV WULJJHUHG DIWHU WKH+RRG KDV
been in operation for 100 working hours.
Fixed
6LJQDOVWKH$FWLYDWHG &KDUFRDO)LOWHU VDWXUDWLRQDODUP7KH¿OWHU PXVWEH
changed after the Hood has been working for 200 hours.