The use of unused conduits is not permissible without the approval of a qualied tech-
nician. The minimum distance between the hob surface and the lowest part of the hood
must be 70 cm. IF the instructions for the cooker installed under the hood require an even
greater distance, this must take precedence.
- INSTALLATION
Beforeinstallingthehood,removetheanti-greaselterstoavoiddamagingtheappliance.To
removetheanti-greaselters,pushthehandletowardthelowerpartofthehoodandrotatethe
lterdownward,removingitfromitshousing(Fig.3A).
Wall stirrup-xing
Byusingthespecialdrillingjig(Fig.4X),perforatethewallaccordingtothepatternindicated
bythejigitself,andpayattentioninordernottodamagewaterpipesandelectricwires.Per-
forationshouldbeperformedwithaØ8mmwall-drill.Theninsertintotheproperplastic
reinforcements(Fig.4A).Thehood-bearingstirrup(Fig.5)canbeappliedbyusingthescrews
providedwiththeequipment(Fig.4S).Nowhookthecookerhoodontoitsbearing(Fig.4B)and
thenadjust horizontallyand verticallythe positionof theappliance byacting onthe special
metricscrews(Fig.7).
Fixing the ornamental chimney
Beforexingthechimney,placetheelectricfeedingequipmentintotheornamentalpipeand
provideitwithaholefortheairoutletiftheapplianceisusedinitssuckingversion.
Discharge mode
Attachthe hosewall mounttothewalland/orceilingwiththescrewexpandersandscrews
(Fig.8Y).Connecttheairdischargeangetothedischargeholewiththepurposehose.
Carryouttheelectricalhookup.Placethetwodecorativeuesonthesuctionunit.Raisethe
internalueuntilitmeetstheceilingandfastenittotheue-mountingunitwiththetwoself-
tappingscrewsincluded.
-Attachthesuctionunits(Fig.6)totheattachedwallmount.Usingtheadjustmentscrews(Fig.
7V),makesurethehoodislevel.
Recirculation mode
Attachthehosewallmounttothewalland/orceilingwiththescrewexpandersandscrews.
Attachtheairdeectortotheupperue(Fig.10)neartheholesmadeonthebackoftheue.
Connecttheairdischargeangetothedeectorwiththepurposehose.
Carryouttheelectricalhookup.
Placethetwouesonthesuctionunit.Adjusttheupperueuntilitmeetstheceilingandfa-
stenittotheue-mountingunitwiththetwoself-tappingscrewsincluded.
Special assembly steps for DHD770X DHD770GW hoods
Forthishood,proceedtoassembletheglasspanelbeforecommencingtheinstallation
-Placetheglass(Fig.14)inthebottompartofthemodulesothattheholesareinlinewiththe
holesinthehoodbody.
-Fasten theglass inplace usingthescrewsprovided anda screwdriver;do nottighten the
screwsexcessively.
Preparation of the fastening screws
Insertthechrome-platedscrew(14D)intotheTeonwasher(14C)andtheninsert thePVC
tube(14b).
34