Nuova Simonelli Aurelia II 2 Gr S [53/214] Hot water economiser adjustment

Nuova Simonelli Aurelia II 2 Gr S [53/214] Hot water economiser adjustment
55
NLI
NOTE: this operation can be carried out while
the machine is turned on.
All models
are equipped with a hot
water mixer tap which adjusts the water tem-
perature and optimises the system’s perfor-
mance.
To adjust the hot water economiser, use a
screwdriver to turn the screw inside the cup
warmer as illustrated in the figure.
Turn it CLOCKWISE / ANTICLOCKWISE to
REDUCE / INCREASE the temperature of
the hot water;
Fig. 19
5.3 HOT WATER
ECONOMISER
ADJUSTMENT
5.4 CLOCK BATTERY
REPLACEMENT
(Digit and T3 ver-
sion only)
The electronic control unit on the Digit and T3
version has a lithium battery to power the clock
and this has a life of around three years, after
which it may be necessary to replace it.
In case the machine has remained unutilised
for a long time, the clock can be blocked by
proceeding as follows:
with the machine off the display will read:
press the key for 5 seconds; the
display will read:
The clock will start up again as soon as the
machine is plugged in once more.
5.5 PUSH-BUTTON
PANEL
REPLACEMENT
Replacement of the lithium battery must be
carried out EXCLUSIVELY by Qualified
Technician.
Nuova Simonelli cannot be held liable for
any damage to people or things due to non
observance of the safety prescriptions
described in this booklet.
For correct functioning of the machine, person-
alising each button panel card at time of
replacement is necessary; proceed as follows
on the selectors placed on the card (on the key
side).
GROUP sw1 sw2 sw3 sw4 sw5 sw6 sw7 sw8
Group 1 On Off Off Off On Off Off Off
Group 2 Off On Off Off Off On Off Off
Group 3 Off Off On Off Off Off On Off
Group 4 Off Off Off On Off Off On Off
WARNING
OFF
STOP CLOCK
At the end of the adjustments, refit the plastic
protection in its housing and fasten it into place
with the two side screws before refitting the
work surface grille.