CHAUVET Nimbus [8/10] Echnical
![CHAUVET Nimbus [8/10] Echnical](/views2/2008316/page8/bg8.png)
Page 8 of 10 Nimbus™ User Manual Rev. 9
4. OPERATION
Basic
Instructions
• The top plate has two LED indicators –
one red and one green. The red LED
indicates that the heater is on, and the green LED indicates when the water is at its
optimal operating temperature. The heater will not turn on unless
there is enough
water.
•
As the dry ice sublimates, the green LED indicator will turn off indicating that the
water temperature has dropped below its optimal operating temperature. This is
normal and the Nimbus™ will continue to operate until all the dry ice has been used.
• During operation, the top plate becomes very hot. DO NOT TOUCH!
•
There is an optional power input next to the main power input to increase the rate in
which the water is heated. Use the included power cable and connect this secondary
input t
o a separate circuit to heat the water in half the time. Do not plug both power
cords into the same circuit as the breaker will trip.
• The dry ice must be stored inside the internal basket for optimal performance. Do not
remove this basket as serious bodily injury may occur.
Operation
1. Place the machine on a level surface. Plug the power cord into the wall.
2. Raise the basket to its highest level with the operation lever.
3. Open the lid and fill with water until the red light comes on. The container can hold up
to 4.5 gallons (17 liters).
4.
Using protective gear, load the basket with up to 10 lbs of dry ice. The dry ice should
be loaded at the last possible moment.
5. Close and latch the lid.
6. Grab the operating lever and slowly lower the handle to the middle notch
for low
output or all the way down for high output.
7. When output slows or stops, raise and refill the basket.
Due to water evaporation, you may need to refill the Nimbus™ with water to trigger the
red LED indicator. Once the red light comes on, repeat steps 4 through 7.
Safety Shutoff
Feature
The Nimbus™ is fitted with a safety shutoff feature, which
prevents the unit’s heaters
from turning on when the water level is too low. If this safety shutoff feature has been
engaged, simply add more water to continue using the Nimbus™.
5. TECHNICAL INFORMATION
Maintenance
The Nimbus requires minimal upkeep in order to maintain optimum performance.
However, some steps are needed in order to clean and maintain the product for
maximum usage. The recommended procedure is as follows:
1. After use, wait for the machine and any remaining water inside to fully cool down.
2. Dump all cooled water from the internal tank from the product. You may risk bodily
harm and damage to transport items if the water is still hot.
Содержание
- User manual 1
- Able of 2
- Ontents 2
- Claims 3
- Conventions 3
- Disclaime 3
- Included 3
- Instructions 3
- Symbols 3
- Unpacking 3
- What is 3
- Safety notes 4
- Carry handle x2 5
- Led indicators 5
- Lid latch 5
- Lid latch x2 5
- Ntroduction 5
- Operation output lever 5
- Optional power in 5
- Output nozzle 5
- Power in 5
- Product overview 5
- Product dimensions 6
- About dry ice 7
- Ac power 7
- And co² 7
- Dry ice 7
- Warnings 7
- Echnical 8
- Feature 8
- Instructions 8
- Maintenance 8
- Nformation 8
- Operation 8
- Peration 8
- Safety shutoff 8
- Be sure to pack the product properly any shipping damage resulting from inadequate packaging will be your responsibility fedex packing or double boxing are recommended 9
- Before sending the product clearly write the following information on a piece of paper and place it inside the box 9
- Call the corresponding chauvet tech support office and request a return merchandise authorization rma number before shipping the product be prepared to provide the model number serial number and a brief description of the cause for the return you must send the merchandise prepaid in its original box and with its original packing and accessories chauvet will not issue call tags clearly label the package with the rma number chauvet will refuse any product returned without an rma number 9
- Chauvet 9
- Chauvet reserves the right to use its own discretion to repair or replace returned product s 9
- Contact 9
- If you live outside the u s united kingdom or ireland contact your distributor of record and follow their instructions on how to return chauvet products to them visit our website for contact details 9
- In the u s contact chauvet world headquarters in the uk or ireland contact chauvet europe ltd in any other country contact your local distributor see www chauvetlighting com for contact details 9
- Information 9
- Procedure 9
- Products to chauvet 9
- Returning 9
- To return a product or request support 9
- Write the rma number on a properly affixed label do not write the rma number directly on the box 9
- Your name your address your phone number the rma number a brief description of the problem 9
- Dimensions and 10
- Echnical 10
- Ordering 10
- Pecifications 10
- Thermal 10
- Weight 10
Похожие устройства
- CHAUVET COLORdash Par Hex 7 Руководство по эксплуатации
- Digitech JamMan Solo XT Руководство по эксплуатации
- CHAUVET SlimPAR Pro QZ12 USB Руководство по эксплуатации
- CHAUVET Freedom H1 X4 Руководство по эксплуатации
- CHAUVET Cumulus Руководство по эксплуатации
- CHAUVET COLORado 1-SOLO Руководство по эксплуатации
- Casio PX-870WE Руководство по эксплуатации
- Casio PX-770 BN Руководство по эксплуатации
- Casio PX-S1000BK Руководство по эксплуатации
- Casio PX-770 WE Руководство по эксплуатации
- Casio PX-770 BK Руководство по эксплуатации
- Casio PX-S3000BK Руководство по эксплуатации
- Casio SP-34 Руководство по эксплуатации
- Casio Privia PX-770BK Руководство по эксплуатации
- Casio GP-300WE Руководство по эксплуатации
- Casio GP-310 BK Руководство по эксплуатации
- Casio GP-310 WE Руководство по эксплуатации
- Casio LK-S250 Руководство по эксплуатации
- Casio CT-S200WE Руководство по эксплуатации
- Casio Celviano AP-470 BK Руководство по эксплуатации