The HOLD function determines how long the signal level is reduced, once the
threshold has been exceeded (upper data wheel). Only when this time has
expired (0 - 1,000 ms), will the RELEASE parameter take over. The control range of
the THRESHOLD parameter (large data wheel) is from 0 to -24 dB, RELEASE can be
adjusted between 20 and 4,000 ms (lower data wheel). A long key press on the B
key resets the LIMITER parameters to their default values.
◊ The LIMITER function is always active and cannot be switched off. It is
also active in bypass mode, however, only works to a limit value of 0 dB,
so as to avoid digital distortion occurring on the outputs.
3.5 UTILITY menu
The UTILITY menu provides basic defaults settings (GENERAL SETUP) and MIDI
congurations on two pages. The upper and lower data wheels select the
parameters, which can then be edited with the large data wheel.
◊ When you keep the UTILITY key pressed for about 1 s, the ULTRACURVE
PRO will be locked and cannot be accessed any longer (PANEL LOCKED).
Keep the key pressed again to unlock the unit (PANEL UNLOCKED).
GENERAL SETUP (page 1)
Fig. 3.16: UTILITY menu (page 1)
CONTRAST
Here you can adjust the display contrast to adapt it optimally to studio/stage
environments (large data wheel).
CHANNEL MODE
As already mentioned, you can choose between DUAL MONO and STEREO LINK
mode. In DUAL MONO mode all settings for the left and right stereo sides can
be entered separately. When you switch to STEREO LINK mode, the settings of
one stereo side will be copied to the other. You can select whether the left side
shall be copied to the right, or the right side to the left (“COPY LEFT -> BOTH” or
“COPY RIGHT -> BOTH”). All subsequent editing will have an eect on both sides
simultaneously. Finally, to activate one CHANNEL MODE, conrm your entry with
the B key (“ACCEPT MODE”).
GEQ MODE (“TRUE RESPONSE”)
Due to the design of conventional equalizers there is always a dierence between
the adjusted frequency response curve and the resulting real frequency response.
This dierence depends on the frequency and the amount of boost/cut applied.
Adjacent frequency ranges have a mutual inuence on each other, so that the
amounts of boost/cut in the individual frequency bands are added together.
Fig. 3.17: Graphic equalizer without frequency response correction (UNCORRECTED)
The setting UNCORRECTED retains this mutual inuence. With a specially
developed algorithm the ULTRACURVE PRO can make up for this phenomenon.
Touse this characteristic, select TRUE RESPONSE.
Fig. 3.18: Graphic equalizer with frequency response correction (TRUE RESPONSE)
The resulting real frequency response now corresponds exactly to the setting
made with the graphic equalizer.
GAIN OFFSET (EQ)
Here, you can correct the overall gain of the EQ modules.
RTA NOISE CORRECTION
The algorithm used by the RTA (Real-Time Analyzer, “warped” FFT) leads to
inaccuracies with wide-spectrum signals such as noise, due to the asymmetric
overlapping of individual frequency ranges. When the built-in noise generator
is on or the AVRG setting in the RTA menu has been selected, this correction will
be made automatically, and needs not be switched on manually. With all other
signals, however, this function should be o; otherwise, the individual frequency
bands might be displayed incorrectly.
SHOW MESSAGE BOX
Here, you can determine whether the unit displays dialog windows or not.
RTA/MIC INPUT
Controls the input sensitivity of the RTA/MIC input. You can choose between
LINELEVEL, MIC LEVEL and MIC LEVEL +15 V (phantom power).
RTA/MIC LINE LEVEL
When the RTA/MIC input is set to LINE, this parameter determines the maximum
input level (for 0 dBFS (full-scale) from -14 to +22 dBu).
RTA/MIC MIC LEVEL
When the RTA/MIC input is set to MIC, this parameter determines the sensitivity
depending on the microphone connected (input sensitivity: -42 to -6 dBV/Pa).
MIDI SETUP (page 2)
Fig. 3.19: UTILITY menu (page 2)
The DEQ2496 can both transmit and receive MIDI data and thus works perfectly
with other MIDI equipment.
Содержание
- Ultracurve pro deq2496 1
- User manual 1
- Table of contents 2
- Important safety instructions 3
- Legal disclaimer 3
- Limited warranty 3
- About this manual 4
- Before you get started 4
- Control elements 4
- Front panel 4
- Introduction 4
- 13 14 15 5
- 16 17 18 19 20 5
- Equalizer modules 5
- General operation and display structures 5
- Menu structure and editing 5
- Rear panel 5
- Width menu 8
- Dyn menu 9
- Utility menu 10
- I o menu 11
- Bypass menu 12
- Rta menu real time analyzer 12
- Memory menu 13
- Applications 14
- Meter menu 14
- Rta mic input 14
- Sum signal equalizer for live applications 14
- Equalizer in the monitor path 16
- Using the ultracurve pro as a delay unit 16
- Using the ultracurve pro in the studio 16
- Analog connections 17
- Connections 17
- Digital connections aes ebu and s pdif 17
- Midi connections 17
- Operating software 18
- Specifications 18
- Wordclock connection 18
- Backlighting led orange 20
- Contrast adjustable 20
- Detectors peak and average 20
- Dimensions h x d x w 44 x 482 x 215 mm 1 5 x 19 x 8 20
- Dimensions weight 20
- Display 20
- Frequency range 20 hz to 20 khz 61 bands according to iso frequencies 20
- Fuse t 1 a h 20
- Hold 0 to 1 000 msec 20
- Limiter 20
- Mains connector standard iec receptacle 20
- Mains voltage 85 to 250 v 50 60 hz 20
- Memory 20
- Midi implementation 20
- Noise generator pink noise levels from 0 to 60 db 20
- Power consumption 10 w typ 20
- Power supply 20
- Presets 64 memory locations with 16 character names single modules can be recalled and saved 20
- Real time analyzer 20
- Release 20 to 4 000 msec 20
- Shipping weight approx 3 9 kg 6 lbs 20
- Threshold variable from 0 to 24 db 20
- Type 320 x 80 dot matrix lc display 20
- Type digital 61 band fft analyzer 20
- Type peak limiter zero attack 20
- Ultracurve pro deq2496 user manual 20
- Weight approx 2 4 kg 4 lbs 20
- Federal communications commission compliance information 21
- Ultracurve pro deq2496 21
Похожие устройства
- Behringer iNUKE NU1000DSP Руководство по эксплуатации
- Behringer STUDIO CONDENSER MICROPHONE C-1 Руководство по эксплуатации
- Behringer EUROLIGHT LC2412 Руководство по эксплуатации
- Behringer iNUKE NU6000DSP Руководство по эксплуатации
- Behringer XENYX QX1202USB Руководство по эксплуатации
- Behringer XENYX Q1202USB Руководство по эксплуатации
- Behringer XENYX 1204USB Руководство по эксплуатации
- Behringer MICROHD HD400 Руководство по эксплуатации
- Behringer ULTRA-DI DI400P Руководство по эксплуатации
- Behringer XENYX 1002B Руководство по эксплуатации
- Behringer MICROMON MA400 Руководство по эксплуатации
- Behringer MICROAMP HA400 Руководство по эксплуатации
- Behringer SONIC ULTRAMIZER SU9920 Руководство по эксплуатации
- Behringer MINIMIX MIX800 Руководство по эксплуатации
- Behringer SONIC EXCITER SX3040 Руководство по эксплуатации
- Behringer MINIFBQ FBQ800 Руководство по эксплуатации
- Behringer TUBE ULTRAGAIN MIC100 Руководство по эксплуатации
- Behringer EUROPORT EPA900 Руководство по эксплуатации
- Behringer EUROPOWER EP4000 Руководство по эксплуатации
- Behringer MICROPOWER PS400 Руководство по эксплуатации