Behringer ULTRACURVE PRO DEQ2496 [20/22] Midi implementation

Behringer ULTRACURVE PRO DEQ2496 [20/22] Midi implementation
20 ULTRACURVE PRO DEQ2496 User Manual
Limiter
Type Peak limiter (zero attack)
Hold 0 to 1,000 msec
Threshold variable from 0 to -24 dB
Release 20 to 4,000 msec
Real-Time Analyzer
Type digital 61-band FFT analyzer
Frequency range 20 Hz to 20 kHz, 61 bands according to
ISOfrequencies
Detectors peak and average
Noise generator pink noise, levels from 0 to -60 dB
Display
Type 320 x 80 dot-matrix LC display
Backlighting LED, orange
Contrast adjustable
Memory
Presets 64 memory locations with 16-character
names, single modules can be recalled
andsaved
Power Supply
Mains voltage 85 to 250 V~, 50/60 Hz
Power consumption 10 W typ.
Fuse T 1 A H
Mains connector Standard IEC receptacle
Dimensions/Weight
Dimensions (H x D x W) 44.5 x 482.6 x 215 mm
(1.75 x 19 x 8.5")
Weight approx. 2.24 kg (4.9 lbs)
Shipping weight approx. 3.09 kg (6.8 lbs)
BEHRINGER is constantly striving to maintain the highest professional standards. As a result of these efforts,
modifications may be made from time to time to existing products without prior notice. Specifications and
appearance may differ from those listed or illustrated.
7.1 MIDI implementation
Function Send Receive Notes
Midi Channel 1 ... 16 1 ... 16
Mode N N
Note Number N N
Velocity N N
After Touch N N
Pitch Bender N N
Control Change
1-31 Y (Range: 0-61) Y (Range: 0-61) GEQ Left (20 Hz ... 20 kHz)
33-63 Y (Range: 0-61) Y (Range: 0-61) GEQ Right (20 Hz ... 20 kHz)
Program Change Y (Range: 0-64) Y (Range: 0-64) Presets (1-64) and Initial Data (0)
System Exclusive Y Y see SysEx-Documentation*
System Common N N
System Real Time N N