Dynacord IPX 5 4 [29/32] Block diagram
![Dynacord IPX 5 4 [29/32] Block diagram](/views2/2013905/page29/bg1d.png)
IPX Series DSP Multichannel Networking Power
Amplifier
Technical data | en 29
Bosch Security Systems, Inc. Installation manual 2018.04 | 01 | F.01U.330.705
8.7 Block diagram
PK
SIG
. .
. .
. .
. .
. . . .
. . . .
. .
. .
. .
. .
PK
SIG
. .
. .
. .
. .
PK
SIG
. .
. .
. .
. .
PK
SIG
. .
. .
. .
. .
. .
. .
. .
. .
. . . .
. . . .
PK
SIG
.
.
.
.
.
.
. .
. .
. .
. .
.
.
.
PK
.
.
SIG
.
. . . .
. . . .
. .
. .
. .
.
.
.
.
.
.
.
.
.
.
.
.
4P
5 . . . 8
OFF
.
.
.
FAILOVER
.
.
.
.
.
.
1P
5P / 5F
4F
8P / 8F
.
.
for Impedance Meas.
.
.
. .
-
+
1
2
3
4
Channel 5 - 8 (only IPX10:8)
5 ... 8
-
+
-
+
-
+
1F
2P
2F
3P
3F
2 3 4
1 2
1 2 3 4
Input 5 - 8 (only IPX10:8)
SOURCE
TRIM
SOURCE
TRIM
SOURCE
TRIM
SOURCE
TRIM
1
2
3
4
same as 1 - 4
1
2
3
1
2
1
2
3
3
1
INPUT 1…4 (1…8 @ IPX10:8)
OUTPUT 1…4 / CURRENT 1…4 (1…8 @ IPX10:8)
DSP Clock
IPX10:8
IPX10:8
OUTPUT METER
GAIN REDUCTION
INPUT METER
IPX10:8
IPX10:8
IPX10:8
DANTE 1
DANTE 8
MONITOR 1
MONITOR 2
Channel 1 - 4
same as 1 - 4
5 . . . 8
5 . . . 8
PRIMARY
FAILOVER
3 4
1
At Dante GLITCHFREE
redundancy mode the
SECONDARY port may
have limited OCA control
data support!
ANALOG 1
ANALOG 2
ANALOG 3
ANALOG 4
ANALOG 5
ANALOG 6
ANALOG 7
ANALOG 8
SOURCE SELECT
1 … 4
5 … 8
1 … 4
5 … 8
PRIMARY
SOURCE
TRIM
PRIMARY
SECONDARY
SOURCE
TRIM
2
3
Input 1 - 4
ARRAY
CONTROL
USER
CONTROL
AMP
CTRL
ARRAY
CONTROL
AMP
CTRL
ARRAY
CONTROL
AMP
CTRL
ARRAY
CONTROL
AMP
CTRL
TEST GENERATOR
Sine / Pink / White
Pre/Mix
Pre/Mix
Pre/Mix
Pre/Mix
Post/Mix
Post/Mix
Post/Mix
Post/Mix
USER
CONTROL
USER
CONTROL
USER
CONTROL
ADC
ADC
Pilot
Detect
& Filter
Pilot
Detect
& Filter
Pilot
Detect
& Filter
Pilot
Detect
& Filter
OMNEO
OCA
Network
Interface
+
DANTE
Source Fail
Detection
+
+
+
+
Output Pilot
Supervision
Load
Supervision
see below
optional
Link
SPEAKER
PROCESSING
SPEAKER
PROCESSING
SPEAKER
PROCESSING
op!onal
Link
optional
Link
ADC
Pilot
Detect
& Filter
ADC
Pilot
Detect
& Filter
see below
SPEAKER
PROCESSING
DELAY
0 to 2000 ms
(686 mtr / 2252 ft)
LEVEL
MUTE
DELAY
0 to 500 ms
(172 mtr / 563 ft)
POLARITY
LEVEL
TRIM
SPEAKER PROCESSING
IIR EQ and X-Over, FIR, Delay, Polarity, Trim,
Peak-Limiter, RMS-Limiter with thermal modelling
LINEAR PHASE EQ
(FIR-based EQing, requires
appropriate control so"ware!)
AMP LIMITERS
& PROTECTIONS
USER CONTROL
only accessible by remote control software
accessible by front panel & remote control
no user access
AMPLIFIER CONTROL
SPEAKER PROCESSING
ARRAY CONTROL
MODE
NORMAL / BRIDGE* /
PARALLEL / PAR-BRIDGE*
DRIVE
Low-Z / 70V / 100V
/ 140V* / 200V*
GAIN
typ. 32dB
@ Low-Z
*) not available in all models or operation modes
optional
Link
optional
Link
optional
Link
EQUALIZER
12 x PEQ / Loshelv / Hishelv / Hipass / Lopass / Notch
(Bands 11 & 12 with additional Asymmetric Shelving)
EQUALIZER
5 bands PEQ / Loshelv / Hishelv
/ Hipass / Lopass / Allpass
configured via speaker settings
MODE
Parallel
Parallel
MODE
MODE
Pilot Tone
op!onal
Link
op!onal
Link
IPX AUDIO SIGNAL FLOW
accessible by remote control software and front panel interface for LEVEL and MUTE
Σ
Σ
Σ
Σ
Σ
Σ
Σ
Σ
Figure8.1: Block diagram: IPX
Содержание
- Table of contents 3
- Important safety instructions 4
- Safety 4
- Safety messages explained 4
- High frequency interference fcc en55032 6
- Safety precautions 6
- Notices 7
- About this manual 8
- Digital document 8
- Manual purpose and intended audience 8
- Application area 9
- Features 9
- System overview 9
- Unpacking and inspection 9
- Scope of delivery 10
- Planning information 11
- Installation 12
- Mains power connection 12
- Mounting 12
- Ventilation 12
- 10 11 12 14
- Control port 14
- Controls indicators and connections 14
- Front panel 14
- Rear panel 14
- Power outputs 15
- Audio inputs 16
- Fan cooling 16
- Display and control menu 17
- Power amplifier menu navigation 17
- Standby and eco rail mode 17
- For further instructions refer to the iris net manual available in the download section of our 18
- Ipx amplifiers can be completely remote controlled and supervised via the iris net software 18
- Remote control via software 18
- Website www dynacord com 18
- Ipx5 4 19
- Technical data 19
- Ipx10 4 21
- Ipx10 8 23
- Ipx20 4 25
- Ipx5 4 ipx10 4 ipx10 8 and ipx20 4 27
- Mains operation resulting temperature 28
- Block diagram 29
- Bosch security systems inc installation manual 2018 4 01 f 1u 30 05 29
- Figure 8 block diagram ipx 29
- Ipx series dsp multichannel networking power amplifier technical data en 29 29
- Dimensions 30
- Accessories 31
Похожие устройства
- Boya BY-HM100 Руководство по эксплуатации
- APart CMAR5-W Руководство по эксплуатации
- Behringer CL2296 Руководство по эксплуатации
- Antari M-7 Руководство по эксплуатации
- Soundmax SM-DM002 Руководство по эксплуатации
- Involight LED PAR984W Руководство по эксплуатации
- Yamaha YPC-91 Руководство по эксплуатации
- Yamaha YSL-697Z Руководство по эксплуатации
- Yamaha YSL-620 Руководство по эксплуатации
- Yamaha YFG-811CII Руководство по эксплуатации
- Yamaha YSL-610 Руководство по эксплуатации
- Yamaha YEP-621S Руководство по эксплуатации
- Yamaha YFB-621 Руководство по эксплуатации
- Yamaha YCR-2310SII Руководство по эксплуатации
- Yamaha YSL-445G(E) (II) Руководство по эксплуатации
- Yamaha YCL-CX-E Руководство по эксплуатации
- Yamaha YCL-CSV Руководство по эксплуатации
- Yamaha YBS-32S(E) Руководство по эксплуатации
- Yamaha YBL-822G Xeno Руководство по эксплуатации
- Yamaha YAS-875EXB Руководство по эксплуатации