Ariston VELIS TECH PW ABSE 100 [49/60] Useful information

Ariston VELIS TECH PW ABSE 100 [49/60] Useful information
49 / EN
USEFUL INFORMATION
Before you clean the unit, make sure you have turned it o by setting its external switch to OFF. Do not use
insecticides, solvents or aggressive detergents: these can damage the unit’s painted and plastic parts.
If the water comes out cold
Disconnect the appliance from the power supply and have the following checked:
- the presence of voltage on the power terminal block (M Fig. 7);
- the circuit board;
- the heating elements;
- inspect the bypass pipe (X Fig. 7);
- the sensor holder rods (K Fig. 7)
If the water comes out boiling hot (steam in the taps)
Disconnect the appliance from the electricity supply and have the following checked:
- the circuit board
- the amount of scale on the boiler and components;
- the sensor holder rods (K Fig. 7).
The hot water delivery is insucient
Disconnect the appliance from the electricity supply and have the following checked:
- the pressure of the water mains;
- the condition of the deflector on the cold water intake pipe;
- the condition of the hot water pipe;
- the electrical components
Water trickling from the pressure safety device
During the healing phase, some water may trickle from the tap. This is normal. To prevent the water trickling, a
suitable expansion vessel must be installed on the flow system. If the trickling continues even after the healing
phase, have the following checked:
- device calibration;
- the pressure of the water mains.
Caution: Never obstruct the appliance outletl
IF THE PROBLEM PERSISTS, NEVER ATTEMPT TO REPAIR THE APPLIANCE YOURSELF, BUT ALWAYS
CONTACT QUALIFIED TECHNICIAN.
The indicated data and specifications are not binding; the manufacturer reserves the right to modify them