Ariston VELIS TECH PW ABSE 80 [45/60] Periodical maintenance

Ariston VELIS TECH PW ABSE 80 [45/60] Periodical maintenance
45 / EN
Replacing parts (when necessary)
The electrical parts may be accessed by removing the cover (Fig. 7).
Intervene on the power board (Fig. 7, Ref. Z) by disconnecting the cables (Fig. 7, Ref. C,Y and P) and remove
the screws. Intervene on the controlpanel by f irst removing the power board (Fig. 7, Ref.Z).
The display board is secured to the product with 2 screws (Fig. 4, Ref. A). After loosening the screws,
press both the tabs with two fingers (Fig. 4, Ref. B) and remove the support (Fig. 4, Ref. C) from its hous-
ing, moving it towards the centre of the product
.
After removing the control panel, you can disconnect the connectors of the rod carrying sensors and power
board. Intervene on the rod carrying sensors (Fig. 7, Ref. K) by disconnecting the wires (Fig. 7, Ref. F) from the
control panel and remove it from its seat, taking care not to excessively bend them.
During reassembly, make sure that all components are put back in their original positions.
The product is equipped with four dry heating elements (Fig. 4B, Ref. R) which are not in direct contact
with the water and can therefore be replaced without emptying the appliance. To replace a malfunction-
ing heating element (identified with a tester), disconnect the relevant Faston connectors (Fig. 4B, Ref. X)
and loosen the screw (Fig. 4B, Ref. V). Remove the damaged heating element and replace it.
To work on the heating elements and anodes, first drain the appliance
.
Remove the bolts
(Fig. 5, Rif. C)
and remove the flanges
(Fig. 5, Rif. F). During reassembly, make sure that
the sensor mounting rods, on which the anodes are mounted, and the heating elements are restored
to their original positions (Figs. 7 and 5).
Make sure that the flange plate with the coloured writing H.E.1 or
H.E.2, is mounted in its position marked by the same writing.
We recommend replacing the f lange gasket (Fig. 6, Ref. Z) every time it is disassembled.
CAUTION! Swapping the heating elements will cause the appliance to malfunction. Work on one element
at a time, and only disassemble the second one after the first one has been reinstalled.
Use only original parts from authorized service centres authorized by the manufacturer.
Periodical maintenance
The magnesium anodes (N Fig. 6) must be replaced every two years or the warranty shall be voided (this does
not apply to appliances with stainless steel boilers); however, the anode should be checked every year if the
water is corrosive or chloride rich. To replace them, remove the heating elements and unscrew them from the
brackets.
The bypass pipe (X Fig. 5) is inspected in the event of fault due to its obstruction. To inspect it remove the two
rings (W Fig. 5).
After routine or extraordinary maintenance, recommend filling its tank with water and draining it completely so
as to remove any residual impurities. Use only original spare parts supplied by the manufacturer’s authorised
service centres
Safety valve
Regularly check that the overpressure device is not jammed or damaged; if it is, remove any scale or replace it.
If the device has a lever or knob, operate it to:
- Drain the appliance, if necessary
- Check its operation from time to time.