Karcher K 5 COMPACT *EU NEW [12/128] English

Karcher K 5 COMPACT *EU NEW [12/128] English
12 English
b Rinse the high-pressure nozzle from the front
with water.
2. Check the water supply volume.
Device leaking
1. The device leaks a small amount for technical rea-
sons. If the leak is severe, request authorised Cus-
tomer Service.
Detergent is not sucked in
1. Use the Vario Power spray lance and turn it all the
way in the "SOFT" direction.
2. Clean the filter on the detergent suction hose.
3. Check the detergent suction hose for kinks.
Warranty
The warranty conditions issued by our relevant sales
company apply in all countries. We shall remedy possi-
ble malfunctions on your appliance within the warranty
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please
contact your dealer (with the purchase receipt) or the
next authorised customer service site.
(See overleaf for the address)
Technical data
Subject to technical modifications.
EU Declaration of Conformity
We hereby declare that the machine described below
complies with the relevant basic safety and health re-
quirements in the EU Directives, both in its basic design
and construction as well as in the version placed in cir-
culation by us. This declaration is invalidated by any
changes made to the machine that are not approved by
us.
Product: High-pressure cleaner
Type: 1.630-xxx
Currently applicable EU Directives
2000/14/EC
2014/30/EU
2006/42/EC (+2009/127/EC)
2011/65/EU
Harmonised standards used
EN 50581
EN 55014-1: 2017
EN 55014-2: 2015
EN 60335-1
EN 60335-2-79
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN 62233: 2008
Conformity evaluation procedure used
2000/14/EC: Appendix V
Sound power level dB(A)
Measured: 86
Guaranteed: 89
The signatories act on behalf of and with the authority of
the company management.
Documentation supervisor: S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2018/10/01
Electrical connection
Voltage V 230
Phase ~ 1
Frequency Hz 50
Connection output kW 2,1
Degree of protection IPX5
Protection class I
Power protection (slow-blowing) A 10
Water connection
Feed pressure (max.) MPa 1,2
Input temperature (max.) °C 40
Input amount (min.) l/min 10
Suction height (max.) m 0,5
Device performance data
Operating pressure MPa 12,5
Max. permissible pressure MPa 14,5
Water flow rate l/min 7,5
Maximum flow rate l/min 8,3
Detergent flow rate l/min 0,3
High-pressure gun recoil force N 20
Dimensions and weights
Typical operating weight kg 13
Length mm 354
Width mm 308
Height mm 520
Determined values in acc. with EN 60335-2-79
Hand-arm vibration value m/s
2
< 2,5
K uncertainty m/s
2
0,7
Sound level L
pA
dB(A) 73
K uncertainty
pA
dB(A) 3
Sound power level L
WA
+ K uncer-
tainty
WA
dB(A) 89
Chairman of the Board of Management
Director Regulatory Affairs & Certification
H. Jenner
S. Reiser

Содержание