Philips AWH1611/51 (50YA) [16/46] Service

Philips AWH1611/51 (50YA) [16/46] Service
14
лампочка - индика
тор работы УЗО (1)
кнопка TEST (2)
кнопка перезапуска (3)
отверстие сброса давления
винт
ручка слива
7
1. Never drain water if its temperature is
above 50 °C, as this may cause burns.
2. If water does not ow, the valve is
damaged. In this case, the water heater
must not be used and it is recommended
tocallaservicetechnician.
Service
1. Check the electrical plug and socket
as often as possible. Reliable electrical
contact must be ensured, as well as
proper grounding. The plug and socket
must not become excessively hot.
2. If the water heater is not used for a long
time, especially in regions with low air
temperature (below 0 °C), to prevent
damage to the water heater (due to freezing
of water in the internal tank), the water from
the heater should be drained.
3. To ensure reliable operation of the water
heater for a long time and maintain
warranty obligations, it is recommended
that regular maintenance by specialists
of authorized service centers is
recommended, during which the internal
tank is cleaned, salt deposits are removed
from the electrical heating elements of
the water heater, and the condition of
the magnesium anode is checked, in case
consumption of half or more is replaced.
The frequency of maintenance of the
water heater depends on the hardness of
the water in the area. Possible intervals
from 3 months to a year.
The frequency of cleaning the tank depends
on the hardness of the water. Cleaning must
be carried out by authorized service centers.
In the warranty card, a note is required that
maintenance is carried out at least once
every 12 months.
4. Preventive work must be carried out
with strict observance of the operating
instructions and safety precautions by
specialists of authorized service centers.
5. In case of water overheating, the thermal
biopolar fuse breaks the electrical circuit on
both sides of the heating element. In this
case, determine the cause of overheating
and reset the thermostat manually by
pressing the reset button located on the
thermostat (or, in case of a malfunction,
replace the thermostat).
6. Remember to check the operation of the
safety valve every 14 days. Check method:
move the drain handle to the upper
position until you feel the transition of
the thread, and then water should ow
from the valve hole.
After checking the water ow, return the
handle to the previous position.
7. Check periodically for scale and blockage.
Drainage of the valve, in order to avoid
clogging, is carried out as follows: if the
valve has a lever, then it must be lifted
several times, if the valve is without a
lever, it must be unscrewed and scale
accumulations removed.