5.3 Four Button Touch Control*
ON&OFF: Starts the motor.
Speed +: Increase the speed of the motor. Max: 3 speed.
Speed -: Decrease the speed of the motor. Max: 1 speed.
Lamp: Turns the lamp on. When the lamp is on, the dot segment is
viewed on the screen.
Timer: If the lamp button is pressed for 3 seconds, the device starts
ashing in respective speed. After 15 minutes the device is turned off.
Air Cleaning: When the air cleaning button is pressed on the
Remote Control, the function is initiated. The motor is operated for 10
minutes in 1 speed, then switches to standby for 50 minutes. While
this function is active, the screen segments start rotating. Then the
system shuts down automatically. The rotation is only for 24 hours.
Filter Warning: At the end of 100 hours of operation, the ‘C’ warning
is viewed on the screen. This warning can be deleted by pressing the
speed - button for 5 seconds, the ‘E’ is viewed on the screen, the
warning is deleted and the timer is reset. This warning is viewed for 2
seconds when on/off button is pressed. During rotation changes this
warning is not displayed.
Automatic Shutdown: For safety purposes, the circuit board of the
motor is programmed to provide maximum of 5 hours lighting and
maximum 10 hours of operation. When the air cleaning function is in
effect, the motor shutdown feature is turned off.
ON/OFF Button Plus Button Minus Button
Lamp
Timer

Похожие устройства

Скачать