6. OPERATING THE CHIMNEY HOOD
Chimney hood is used in ducted and non-ducted kitchens.
6.1. In Ducted Use
In ducted use, extractor fan should be connected to an air outlet to
send the air out. In order to use your chimney hood efciently, make sure
length of the pipe system between the chimney hood and the air outlet
should be short. Your product has been manufactured suitable for ducted
and non-ducted use.
6.2. Round Charcoal Filter
In kitchens with no duct, a round charcoal lter should be reintroduced
the clean air into the kitchen. You can obtain the round lter from your
service or dealer.
6.3. Use Of Charcoal Filter
Our products allow the installation of charcoal lter.
Regardless of use of charcoal lters or not, grease lters should be
installed on the product. Do not use your product without grease
lter.
Use of charcoal lteris as follows.
Cut off the device power before replacing charcoal lter.
Charcoal lter is used in the kitchens with no duct therefore should
be replaced in every 3-5 months depending on the frequency of use.
Charcoal lter should never be washed.
6.4. Installation Of Charcoal Filter
Charcoal lters are used in the kitchens with no duct.
Charcoal lters are installed onto both sides of the fan as shown in
Figure 10 by turning 10 degrees clock-wise.
When uninstalling, reverse the same procedure.
6.5. Use Of Aluminum Cartridge Filter
Aluminum cartridge lter holds dust and grease in the air. Chimney
hoodshould never be used without aluminum cartridge lter. (Figure 11)
Installing Position
Figure 10
Figure 11