Oursson FZ0805 белый [8/60] Possible problems and solutions

Oursson FZ0805 белый [8/60] Possible problems and solutions
8
POSSIBLE PROBLEMS AND SOLUTIONS
Possible problems Possible causes Solutions
Device isn’t working.
There is no voltage in the mains.
The cord is plugged incorrectly.
Turn on the device.
Check the main and the plug. If they are
working, call the service center.
Vibrating noise. The device is in unstable position.
Adjust the position of the device.
Move it if necessary.
The temperature is not cold
enough.
The door is not closed rmly.
Not enough ventilation.
Make sure the door is rmly closed.
Clean the vents.
The compressor is operating
for a long period.
Ambient temperature is too high.
The door is opened too often or
remains open.
Adjust the temperature of the room.
Make sure the door is rmly closed.
Please check the possible problems before contacting a service center
Specications
Model FZ0805
Refrigerant R600a
Refrigerant weight 35 g
Reversible doors Yes
Total capacity, L 80
Freezer chamber capacity 71
Power consumption class А+
Power consumption, kW•h/year, W•h/day 68 kW, 460 W
Climatic class N/SN/ST
Level of noise less than 42 dB
Minimum freezing temperature up tо -24°C
Freezing performance, kg/h 4,0
Rated voltage 220-240 V~, 50 Hz
Storage and transportation temperature -25°C tо +35°C
Operating temperature from +5°C tо +35°C
Humidity Requirements 15-75% without condensate
Class of protection I
Dimensions HxWxL, mm 835х486х536
Weight, kg 28
* Products must be stored in dry, ventilated warehouses at a temperature not lower than -25°С.
ZERTIFIZIERUNG
Hinweise zur Produktzertizierung nden Sie unter http://www.oursson.com;
Sie können auch Ihren Händler danach fragen.
Reparaturen dürfen nur über den Kundendienst der OURSSON AG ausgeführt werden.