7 BEFORE CALLING AFTER-SALES SERVICE
Errors
Your fridge will warn you if the temperatures for the cooler and freezer are at improper
levels or if a problem occurs with the appliance. Warning codes are displayed in the freezer
and cooler indicators.
ERROR TYPE MEANING WHY WHAT TO DO
SR "Failure" Warning
There is/are some
part(s) out of order or
there is a failure in the
cooling process.
Call a service agent for assistance as
soon as possible.
LF
Freezer compartment is
not cold enough
This warning especially
appears if there has
been a power failure
for a long period or
when the refrigerator is
operated for the rst
time.
1. Use food within a short time period.
Do not freeze foods that has thawed.
2. Set the freezer temperature to colder
values or set the Super Freeze until
the compartment gets to normal
temperature.
3. Do not put fresh food in the appliance
until the fault has cleared.
LC
Refrigerator
compartment is not cold
enough
This warning especially
appears if there has
been a power failure
for a long period or
when the refrigerator is
operated for the rst
time. Ideal temperature
for the refrigerator
compartment is +4
o
C.
If you see this warning,
your foods are at risk of
spoiling.
1. Set the refrigerator temperature
to colder values or set the Super
Cooling mode until the compartment
reaches normal temperature.
2. Open the door as little as possible
until the fault clears.
LF and LC
"Not cold enough"
Warning
This is a combination
of the LF and LC error
types.
You will see this failure when rst
starting the appliance. It will clear
after the compartments reach normal
temperature.
HC
Refrigerator
compartment too cold
The food will start to
freeze because the
temperature is too cold.
1. Check if the Super Cooling mode is
switched on.
2. Decrease the refrigerator
temperature values.
LOPO "Low voltage" Warning
This is seen when the
power supply becomes
lower than 170 V.
This not a failure. This prevents any
damage to the compressor. This warning
will clear after the voltage reaches the
required level.
If you are experiencing a problem with
your appliance, please check the following
before contacting the after-sales service.
Your appliance is not operating
Check if:
There is power
The plug is correctly placed in the socket
The plug fuse or the mains fuse has
blown
The socket is defective. To check this,
plug another working appliance into the
same socket.
The appliance performs poorly
Check if:
The appliance is overloaded
The appliance door is closed properly
There is any dust on the condenser
There is enough space near the rear and
side walls.