Oleo-Mac PW 125 C 6850-9101 [19/88] Features and technical specifications

Oleo-Mac PW 125 C 6850-9101 [19/88] Features and technical specifications
19
GB
USAGE
WARNING: First of all read the General Sec-
tion and then this Specic Manual
.
> PUT INTO SERVICE
See g.
A
> STARTING UP
See g.
B
> HIGH PRESSURE LANCE
See g.
D
> DETERGENT SUCTION
See g.
E
> HIGH PRESSURE HOSE
See g.
F
> WATER SUPPLY
Water supply collection
WARNING (symbol):
machine not suitable
for connection to the potable water mains.
The cleaner can only be connected to the
water mains if the water mains is separated by
a backow preventer.
Make sure that the hose is at least Ø 13mm-1/2
inch and that it is reinforced.
WARNING: Water that has own through
backow preventers is considered to be non-
potable
.
EFCO IP 1250 S
OLEO-MAC PW 125 C
ELECTRICAL CONNECTION
Mains power supply 220-240 V - 1 ~ 50/60 Hz
Absorbed power 2,35 kW
Fuse 16 A
HYDRAULIC CONNECTION
Maximum inlet water temperature 40 °C - 98 °F
Minimum inlet water temperature 5 °C - 41 °F
Minimum inlet water ow 900 l/h - 15 l/min - 172 US gph
Maximum inlet water pressure 1 MPa - 10 bar - 145 psi
Minimum inlet water pressure 0,1 MPa - 1 bar - 14,5 psi
PERFORMANCE
Water ow 498 l/h - 8,3 l/min - 131,5 US gph
Maximum pressure 15 MPa - 150 bar - 2176 psi
Recoil of cleaner gun 12 N
Sound pressure level - Uncertainty (*) 79 dB(A) - 0,7 dB(A)
Sound power level 94 dB(A)
Operator arm vibrations - Uncertainty (*) 1,5 m/s² - 0,5 m/ s²
WEIGHT AND DIMENSION
Lenght x width x height 330 x 280 x 840 mm - 13 x 11 x 33 in
Weight 8,6 kg - 19 lb
Detergent bottle capacity 0,7 l - 0,18 US gal
(*) Measurements taken in compliance with EN 60335-2-79
All features and technical specications are only indications. The Manufacturer reserves the right to modify the appliance as it
deems necessary.
FEATURES AND TECHNICAL
SPECIFICATIONS