Sharp черный/графит KIN41RH 64942940 [66/68] Specifications

Sharp черный/графит KIN41RH 64942940 [66/68] Specifications
EN-19
ENGLISH
SPECIFICATIONS
Model KI-N51R KI-N41R
Power supply 220 - 240 V ~ 50 - 60 Hz
Fan Speed Adjustment MAX MED LOW MAX MED LOW
CLEAN AIR
Fan Speed (m
3
/ hour) 306 168 60 240 150 60
Rated Power (W) 51 17 5.5 29 14 5.5
Noise Level (dBA) *
1
51 40 17 46 38 17
CLEAN AIR
&
HUMIDIFY
Fan Speed (m
3
/ hour) 252 186 66 174 138 60
Rated Power (W) 32 22 6.7 17 15 6.5
Noise Level (dBA) *
1
47 43 20 38 35 19
Humidification (mL / hour) *
2
600 480 200 440 370 190
Standby power (W) 1.2
Recommended Room Size (m
2
) *
3
~ 38 ~ 28
High density Plasmacluster ion
recommended room size (m
2
) *
4
~ 21 ~ 17
Water Tank Capacity (L) Approx. 2.7
Sensors Sensitive Dust / Odor / Light / Temperature & Humidity
Filter Type HEPA*
5
/ Deodorizing / Humidifying
Cord Length (m) 2.0
Dimensions (mm) 384 (W) × 230 (D) × 619 (H)
Weight (kg) Approx. 8.2
*1
Noise level is measured based on the JEM1467 standard of the Japan Electrical Manufactures' Association.
*2
The amount of humidification changes in accordance with indoor and outdoor temperature and humidity.
The amount of humidification increases as temperatures rises or humidity decreases.
The amount of humidification decreases as temperatures decrease or humidity rises.
Measurement Conditions: 20 ºC, 30 % humidity (according to JEM1426).
*3
The recommended room size is appropriate for operating the product of maximum fan speed.
The recommended room size is an area in which a given amount of dust particles can be removed in 30 minutes
(according to JEM1467).
*4
Room size in which approximately 25000 ions per cubic centimeter can be measured in the center of the room when the
product is placed next to a wall, is running at MED mode settings, and is at a height of approximately 1.2 meters from the
floor.
*5
The filter removes more than 99.97% of particles at least 0.3 microns in size (according to JEM1467).
Standby Power
When the product’s power plug is inserted in a wall outlet it consumes standby power in order to operate electrical circuits.
To conserve energy, unplug the power cord when the product is not in use.
KI-N51R_41R_2nd.indb 19KI-N51R_41R_2nd.indb 19 2021/10/01 16:39:352021/10/01 16:39:35

Содержание

Похожие устройства