Operation notes
1. Please don’t operate this product unless the manual has been read.
2. To assure accuracy, remove the protection cap and make sure the sensor is fully exposed before taking any measurement.
3. Remove the battery before long term storage. Keep the sensor part away from water or any kind of liquid.
4. To assure accuracy after calibration, do not expose the sensor in saturated environment for long.
5. To avoid damages to the instrument, do not operate near following places
a) Vapor and dusty places
b) EMF places (Electro-magnetic fields: such as arc welders, induction heaters)
c) Static environment
d) Heat shock (caused by great and sudden temperature change), wait for 30 minutes until the unit is stabilized before any operation.
6. After long working hours, the sensor may be polluted and the electronic parameters happen to drift. If the measured value is out of the actual
measuring range, these steps as follows should be taken to calibrate.
7. Please purchase the standard 33% and 75% humidity salt bottle in the market.
A) Please press to deactivate auto power off function and turn the unit on (press the upper left button, then press the middle
power button. When the screen be full-displayed, release the upper left button until the normal humidity and temperature values show
on the screen).
B) Remove the sensor protection cap and press the upper left button and right button. simultaneously . “---” will appear
under the screen and “1” will appear on the right side of it. Put the sensor part in the 33% humidity salt bottle for at least 40 minutes.
After 40 minutes, the unit adjusts the value to 33% automatically.
C) Take out the unit and press the upper left and right button simultaneously. “---”appears under the screen and “2” appears
on the right side of it. Put the unit in the 75% standard humidity box for more than 40 minutes. After 40 minutes, the unit adjusts the
value to 75% automatically. The calibration work is finished only after the calibration of two continual values.
The unit must go through two (“1”-->“2”) regular calibrations. In this way, the calibrations are effective. Moreover, the oder of the
calibration values can’t be opposite. Firstly, calibrate in 33% salt bottle, then in the 75% salt bottle. If calibrations are done in 33% salt
Содержание
Похожие устройства
- Ada ZHT 100-70 А00516 Инструкция по эксплуатации
- Ada ZHT 100-70 с калибровкой А00516К Инструкция к товару
- МЕГЕОН 18005 к0000017665 Инструкция по эксплуатации
- Legrand Celiane 067049 Инструкция к товару
- МЕГЕОН 16401 к0000031910 Инструкция по эксплуатации
- Атмосфера Нордик 00-00015905 Инструкция по сборке
- ФЕЛИКС 40x38.6x44.5 белый ПК-МКП-ТМК40Х39-В1-76 Инструкция
- ФЕЛИКС 40x38.6x44.5 белый ПК-МКП-ТМК40Х39Я1-В1-76 Инструкция
- Шведский Стандарт КАСТОР 2 ящика, 39x37x49 см, белая 2.03.03.050.1 Инструкция по сборке
- Шведский Стандарт КАСТОР 2 ящика, 39x37x49 см, бежевая, дуб сонома 2.03.03.050.3 Инструкция по сборке
- Шведский Стандарт СИРИУС 1 ящик, 41x39x53 см, бежевая, дуб сонома 2.02.03.010.3 Инструкция по сборке
- Шведский Стандарт СИРИУС 1 ящик, 41x39x53 см, черная, дуб венге 2.02.03.010.5 Инструкция по сборке
- Puty PT-50DC переносной PT50DC 408543 Инструкция
- Puty PT-100E ручной, кириллица/латиница 408573 Инструкция
- Puty PT-100ECH ручной рус/англ печатает только на лентах Vell CH (аналог Brother PT E110, PT H110, Dymo D210) 1350565 Инструкция
- Атол BP41 40778 Инструкция к товару
- MPRINT TLP100 TERRA NOVA Ethernet, RS232, USB black 4588 Инструкция к товару
- Cactus CS-LP1120NWW A4 белый (в комплекте: картридж + кабель USB, Ethernet) 1989134 Инструкция по эксплуатации
- Ника Игрушка принтованный ТБ5К-90/12 snowracer Инструкция к товару
- Техно Вектор V 8218 Инструкция