Makita DCL281FZ 197949 [12/92] Operation

Makita DCL281FZ 197949 [12/92] Operation
12 ENGLISH
Reassembly
Connecthighperformancelter.Atthistime,makesure
totwisthighperformanceltersothatsecuringlipis
rmlylockedintothecleanerunit.
►Fig.13: 1.Highperformancelter
►Fig.14: 1. Securing lip
NOTICE: Always be sure to check that high perfor-
mancelterisloadedcorrectlypriortousingcleaner.
If they are not loaded correctly, dust will get into the
motor housing, and cause motor failure.
If the problem as described later occurs, high per-
formancelterisnotloadedcorrectly.Reloadthem
correctly to rectify problem.
Attach the capsule. Align the mark on capsule with the
markonthehandleandthenrmlytwistcapsuleinthe
direction of arrow until it is secured.
►Fig.15: 1. Mark 2. Handle 3. Capsule
NOTE: Always remove dust ahead of time, as suction
power will be reduced if there is too much dust in
cleaner.
Problem Examples
Thesecuringlipofhighperformancelterisnotrmly
locked into groove of cleaner housing.
►Fig.16: 1. Securing lip 2. Groove of cleaner housing
Installing or removing stay / HEPA
lter
Optional accessory
For the stay and sponge lter
To remove the stay, push up the bottom part of pillars
ofthestaywithyourngersandreleaseitsgroovefrom
the protrusion on the cleaner. After that, remove the
spongelter.
►Fig.17: 1. Stay 2.Spongelter
To install, align the grooves on the stay with the protru-
sion on the cleaner and push until it clicks.
Insertthespongelterbetweenthepillarsandsetitin
the original position.
For the HEPA lter
WheninstallingtheHEPAlter,tthegrooveofthe
HEPAlterwiththeprotrusiononthecleaner.Then,put
theprelterorthehighperformancelterontheHEPA
lterandtwistittosecure.Toremove,followtheinstal-
lation procedure in reverse.
►Fig.18: 1.HEPAlter2.Prelter
►Fig.19: 1.HEPAlter2.Highperformancelter
OPERATION
CAUTION: Do not move your face close to
the air vent when operating the cleaner. If foreign
objectsareblownintoeyes,itmayresultinpersonal
injury.
Installing or removing the cleaner
attachment
CAUTION: After installing attachment,
check if it is securely installed. If the attachment
isinstalledimperfectly,itmaycomeo󰀨andcause
personalinjury.
CAUTION: Be careful not to hit your hand on
the wall etc. when removing the attachment.
When using attachment with lock
function
To install attachment, insert it to the suction inlet of the cleaner
until it clicks. Make sure that the attachment is locked.
►Fig.20: 1. Suction inlet 2. Attachment with lock
function 3. Hook
NOTE: When installing the attachment with lock
function, be sure to align the release button with
the hook on the attachment. If they are not aligned,
thewandwillnotbelockedandmaycomeo󰀨from
the cleaner.
To remove, pull the attachment while pushing the
release button.
►Fig.21:
1. Release button 2. Attachment with lock function
When using attachment without lock
function
CAUTION: To connect attachment without
lock function, twist and insert it in direction of
the arrow to secure the connection during use.
To disconnect the attachment, twist and extract
it also in direction of the arrow. If the attachment
is twisted in the opposite direction, the capsule may
become loose.
►Fig.22
Cleaning (Suction)
Nozzle
Attachthenozzletocleano󰀨tables,desks,furniture,
etc. The nozzle slips on easily.
►Fig.23: 1. Nozzle
Nozzle + Extension wand (Straight pipe)
Theextensionwandtsinbetweenthenozzleandthe
cleaner itself. This arrangement is convenient for clean-
ingaoorinastandingposition.
►Fig.24: 1. Cleaner body 2. Extension wand
3. Nozzle