Contracor 10130810 [9/36] Maintenance frequency

Contracor 10130810 [9/36] Maintenance frequency
CONTRACOR
®
COMFORT Art. 10130810
9
Airline lter CONTRACOR
®
BAF.
For further information about the airline lter unit CONTRACOR
®
BAF refer to the
supplied manual documentation.
After replacing the components carry out a functional check.
Functional check: After cleaning, disinfecting or exchanging components check
the functioning of the system. Inspect all essential components for damage or pollution
and, if required replace these with original spare parts. If the yellow pennant of the airow
indicator shows insufcient air in the abrasive blasting helmet, although the pressure is
correctly adjusted, this could indicate that a blockage has occurred in the compressed
air hose, coupling or silencer. During this check, hold the abrasive blasting helmet in the
vertical (normal working) position.
Checking hose system for leakages: Test air supply hose and coupling parts
manually on pull force. Connect abrasive blasting helmet to the compressed air system and
adjust the supply pressure. Air supply hose and couplings may not give leak sounds.
4. Maintenance frequency.
Clearance to start use: Function and leakage inspection.
Prior to use: Performance check for the user, check of
control valve.
After use: Cleaning and disinfecting of the abrasive blast-
ing helmet: cleaning, functional checking and
leakage inspection of the complete system.
Every 6 months: Cleaning and disinfecting of the abrasive blast-
ing helmet: cleaning, functional checking and
leakage inspection of the complete system.