LG PQRCUSA0 [8/27] Installer setting thermistor

LG PQRCUSA0 [8/27] Installer setting thermistor
Owner’s & Installation Manual 15
ENGLISH
Installation instruction
Function Code Thermistor setting
Press button for 4 seconds
to enter the installer setting
mode until timer segment
display 01:01.
1
Set Thermistor mode by pressing
button. (01: Remote Controller,
02: Indoor, 03: 2TH)
3
Press button to save or release.
4
Press button to exit or
system will automatically exit
after 25 seconds without any
input.
5
Repeat pressing button to select
Function code 04.
Ex) Setting Thermistor as '2TH'.
2
Installation instruction
14 Wide Wired Remote Controller
Installer Setting -Thermistor
Therefore system will use value that sensed from indoor unit or remote controller
Press button to save or release.
6
Press button to exit or the system
will automatically exit after 25 seconds
without any input.
7
Weak and Power setting is not available for some products.
Because the ESP value is already appropriately set when manufactured from the factory, it is
recommended that you do not change the ESP value.
<Thermistor Table>
Temperature sensor location Function
01 Remote controller Operation in remote controller Temperature sensor
02 Indoor unit Operation in indoor unit temperature sensor
03 2-Thermistor(2TH)
Operation in lower temperature after comparing the temperature between
the indoor unit and remote controller

Содержание