Похожие устройства

User Manual User Manual Checking the horizontal line Position the device about 5 m from a wall and switch on the cross laser Mark point B on the wall Turn the laser cross approx 2 5 m to the right and mark point C Check whether the horizontal line from point C is level with point B to within 2 mm Repeat the process by turning the laser to the left Performing the calibration check 3 Position the device as near as possible to the wall at the height of point A1 4 Turn the device through 180 and mark point A3 The difference between points A1 and A3 is the tolerance MOUNTING OPTIONS When A1 and A3 are more than 4 mm 10 m apart an adjustment is necessary Contact your authorised dealer or else CONDTROL Service Department Checking the vertical line Position the device about 5 m from a wall Fix a plumb bob with aline of 2 5 m length on the wall making sure that the bob can swing freely Switch on the device and align the vertical laser to the plumb line The precision is within the specified tolerance if the deviation between the laser line and the plumb line is not greater than 1 5 mm llll llll llll llll llll llll llll llll llll llll llll llll llll llll llll llll llll lll