Bosch GMS 120 Prof 0601081004 Инструкция к товару онлайн [26/455] 860366

Bosch GMS 120 Prof 0601081004 Инструкция к товару онлайн [26/455] 860366
26 | English
If, after having completed this measurement, you want to start a new measuring pro-
cess on another wall, briefly press the Drywall operating mode button(11) in order to
reset the measuring tool.
In rare cases, the measuring tool is not able to detect the base material because the
sensor area(13) on the rear side is dirty. Clean the measuring tool with a soft, dry
cloth and re-start the measuring process.
Metal operating mode
Metal operating mode is particularly suited to detecting magnetic and non-magnetic ob-
jects, regardless of the nature of the wall.
To activate Metal operating mode, press the Metal operating mode button(10). The
light-up ring(1) and the operating mode indicator(4) above the Metal operating mode
button will light up green.
If the measuring tool passes over a metal object (the light-up ring(1) will light up red),
the type of metal will be shown in the display. For magnetic metals (e.g. iron) the Mag-
netic metal indicator(e) will appear, for non-magnetic metals (e.g. copper) the Non-
magnetic metal indicator(d) will appear.
Note: For reinforcement steel mesh and reinforcements in the examined based material,
an amplitude is indicated over the entire surface in the measuring indicator(i). For rein-
forcement steel mesh, it is typical that the magnetic metal indicator(e) appears directly
above the iron rods, whereas the non-magnetic metal indicator(d) will appear between
the iron rods.
Power cable operating mode
Power cable operating mode is only suitable for detecting live wires (110−230V).
To activate Power cable operating mode, press the Power cable operating mode
button(9). The light-up ring(1) and the operating mode indicator(4) above the Power
cable operating mode button will light up green.
When a live wire is detected, the indicator for live wires(f) will appear on the display.
Move the measuring tool over the surface again in order to locate the live wire more pre-
cisely. After moving the measuring tool over the surface multiple times, the live wire can
be detected very precisely. If the measuring tool is very close to the wire, the light-up
ring(1) will flash red and the audio signal will sound at a faster rate.
Notes:
Live wires are detected in every operating mode.
Live wires can be detected more easily when power consumers (e.g. lamps, appli-
ances) are connected to the wire being sought and switched on. Switch off electricity
consumers before drilling, sawing or milling into the wall.