Piusi K900 METER 3in BSP F0049900B Инструкция онлайн [49/60] 865689
![Piusi K900 METER 3in BSP F0049900B Инструкция онлайн [49/60] 865689](/views2/2103824/page49/bg31.png)
49/124
49 /6 0
EN
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
Translated from Italian
8
LONG RESET KEY KEYING
K900 is informed that the calibration procedure is finished. Before doing this, make
sure the DISPLAYED factor is the ACTUAL factor
Indicated value Real value
K900 calculates the new USER K FACTOR ; this calculation could require a few sec-
onds, depending on the correction to be made.
During this operation the arrow disappears but the CAL indication remains.
If this operation is performed aer operation (5), without changing the indicated value,
the USER K FACTOR would be the same as the FACTORY K FACTOR, thus it is ig-
nored.
9
NO OPERATION
At the end of the calculation, the new USER K FACTOR is shown for a few seconds,
aer which the restart cycle is repeated to finally achieve standby condition.
IMPORTANT: From now on, the indicated factor will become the calibration factor used
by the meter and will continue to remain such even aer a baery change
10
NO OPERATION
K900 stores the new calibration factor and is ready
for dispensing, applying the newly defined USER K FACTOR.
I2.3 DIRECT MODIFICATION OF K FACTOR
This procedure is especially useful to correct a “mean error” obtainable on the basis of several performed
dispensing operations. If normal K900 operation shows a mean percentage error, this can be corrected
by applying to the currently used calibration factor a correction of the same percentage. In this case, the
percentage correction of the USER K FACTOR must be calculated by the operator in the following way:
New cal. factor = Old cal. factor * (
100 - E%
100
)
Example Error percentage found E% - 0.9 %
CURRENT calibration factor 1,000
New USER K FACTOR 1,000 * [(100 – ( - 0,9))/100]=
1,000 * [(100 + 0,9)/100] =
1.009
If the meter indicates less than the real dispensed value (negative error) the new calibration factor must be
higher than the old one as shown in the example. The opposite applies if the meter shows more than the
real dispensed value (positive error).
Похожие устройства
- Piusi K900 METER 3in BSP F0049900B Инструкция
- Ryobi RB18L90 5133002865 Таблица времени работы инструментов ONE+ с аккумуляторами разной емкости
- ТАУ СЧЕТ-1М 00000002083 Инструкция по эксплуатации
- ТАУ СЧЕТ-1М 00000002083 Свидетельсво об утверждении типа
- ТАУ СЧЕТ-2 00-00000047 Инструкция по эксплуатации
- ТАУ СЧЕТ-2 00-00000047 Свидетельство об утверждении типа
- ТАУ СЧЕТ-2 00-00000047 Методика поверки секундомера СЧЕТ-2
- CNIC Шан 115-320 20-170 0.01, для внутренних канавок, Н-40 мм, нержавеющая сталь 31463 Инструкция к CNIC Шан 115-320 20-170 0.01 31463
- CNIC Шан 115-325 25-225 0.01, для внутренних канавок, Н-50 мм, нержавеющая сталь 31464 Инструкция к CNIC Шан 115-325 25-225 0.01 31464
- CNIC Шан 116-320 0-150, 0.01, для наружных канавок, H-40 мм 35181 Инструкция к CNIC Шан 116-320 0-150, 0.01 35181
- Kinex (K-MET) ШЦЦ-1 150мм, 0.01мм, DIN862 ABSOLUTE ZERO 6040-05-150 Письмо
- RGK SC-150 779487 Руководство по эксплуатации Штангенциркуль электронный SC-150
- RGK SC-200 779494 Руководство по эксплуатации Штангенциркуль электронный SC-150
- RGK SC-300 779500 Руководство по эксплуатации Штангенциркуль электронный SC-150
- ORAS Optima Bluetooth 1714FZ 00000083716 Инструкция к товару
- AM.PM F50A02400 инструкция
- EKF Минск ОП 10А без заземления, белая, Basic EGR10-102-10 Паспорт
- Deko DKIT04 с шаровым механизмом, меню на русском языке 065-0957 Инструкция по эксплуатации
- Deko DKIT05 c широким дисплеем 065-0346 Инструкция по эксплуатации
- Verto 15G751 15G751