Kospel 4 кВт EPO.G-4 [17/32] Flow regulation

Kospel Amicus EPO,D-6 [17/32] Flow regulation
17
PL;DE;FR;GB;LT;LV;RU-004AB_f.749
Flow regulation
1. Openthehotwatertaptothemaximumwater
owrate.
2. Insertthescrewdriverintotheregulationvalve
andsettherequestedwaterowrate.
3. Closethehotwatertap.
Maintenance
Properowsettingsoptimiseunitperformance.Temperatureofwaterdependson
theowrate–thehigherowratethelowerwatertemperature.
Venting
1. Shut off electric supplies to the heater.
2. Turntheowon(turnthehotwatertapon)inordertoventthewaterinstallation
(forabout15-30seconds),untiltheowofwaterbecomesconstantandeven.
3. Turntheowoff(turnthehotwatertapoff).
4. Switchontheelectricsupplies.
The venting process must be repeated each time after the water has been
emptied from the unit or pipes.
1. Cutoffpowerandcoldwatersupplies.
2. Undothettingsontheinletpipe.
3. Takethelteroutfromthettingsatthecoldwaterinlet.
4. Cleanandinstallthelterintheformerposition.
5. Connectcoldwatersupplypipewiththeinletpipe.
6. Openthecut-offvalveoncoldwatersupplypipe-checkconnectionsforleaks.
7. Venttheunitandwatersystem.
Operating
Theunitisequippedwithadifferentialpressureswitch.Itswitchesheatingwhen
thereisaproperwaterowthroughtheunit.
Therearetwoindicatorsonthecase:
- green-powersupply“on”,
- red-heating“on”.
GB