Zalman ZM400-LE [4/5] Zm500 le cable specifications
![Zalman ZM400-LE [4/5] Zm500 le cable specifications](/views2/1111331/page4/bg4.png)
33
3. Specications
3) ZM500-LE Electrical & Physical Specications
4) ZM500-LE Cable Specications
AC Input Range
Voltage 220 or 230VAC
Vout
Output Load Rating
Combined
Power
Frequency 47Hz ~ 63㎐ I
min
I
max
I
peak
AC Input Current
220VAC
4.5A
+3.3V 0.1A 18A
120W
500W
230VAC +5V 0.2A 15A
PFC Type
None PFC
+12V1 0.1A 20A
444W
Power Factor Correction Max 50% +12V2 0.5A 20A 22A
Inrush Current Limit
(@ Cold Start at 25℃)
220VAC
Max 100A
-12V 0.0A 0.3A 3.6W
230VAC +5VSB 0.0A 2.0A 3.0A 10W
Eciency Max 81% @ 230VAC, Typical load Ambient Temperature
DC Output Voltage
Regulation
Vout Stable Range
At
Full
Load
Operation 0℃ ~ +40℃
+3.3VDC ±5% +3.14 ~ +3.47V Stored -40℃ ~ +70℃
+5VDC ±5% +4.75 ~ +5.25V Ambient Humidity
+12V1DC ±5% +11.4 ~ +12.6V Operation 5% ~ 85% RH
+12V2DC ±5% +11.4 ~ +12.6V Stored 5% ~ 95% RH
-12VDC ±10% -10.8 ~ -13.0V Product Dimensions
+5VSB ±5% +4.75 ~ +5.25V 140 (L)
*
150 (W)
*
86 (H) mm
DC Output Ripple
& Noise
Vout Standard Range
At
Full
Load
Product Weight
+3.3VDC 50mV 1.8 kg (Full Package)
+5VDC 50mV Protection Funtions
+12V1DC 120mV Over-Voltage Protection (OVP)
+12V2DC 120mV Under-Voltage Protection (UVP)
-12VDC 120mV Short- Cicuit Protection (SCP)
+5VSB 50mV Over-Power Protection (OPP)
PCI Express2
Power Connector
PCI Express1
Power Connector
Mainboard Power
Connector
CPU Power
Connector
S-ATA Power
Connector
S-ATA Power
Connector
S-ATA Power
Connector
S-ATA Power
Connector
S-ATA Power
Connector
ODD/HDD Power
Connector
S-ATA Power
Connector
ODD/HDD Power
Connector
ODD/HDD Power
Connector
FDD Power
Connector
150
±10mm
500
±20mm
500
±20mm
500
±20mm
450
±20mm
150
±10mm
150
±10mm
400
±20mm
150
±10mm
150
±10mm
400
±20mm
150
±10mm
150
±10mm
150
±10mm
Содержание
- Power supply 1
- Two forward switching 1
- Users manual 1
- Www zalman com 1
- Zm400 500 le 1
- Ac power cord 2
- Components 2
- Disclaimer zalman tech co ltd is not responsible for any damages due to external causes including but not limited to improper use problems with electrical power accident neglect alteration repair improper installation or improper testing 2
- Five cable ties 2
- Four screw 2
- Power supply 2
- User s manual 2
- Warnings and safety precautions 2
- Specifications 3
- Zm400 le cable specifications 3
- Zm400 le electrical physical specifications 3
- Specifications 4
- Zm500 le cable specifications 4
- Zm500 le electrical physical specifications 4
Похожие устройства
- Sony VAIO VPCEB4S1R Инструкция по эксплуатации
- Sony Xperia Z3 Dual D6633 White Инструкция по эксплуатации
- Zalman ZM500-LE Инструкция по эксплуатации
- Sony VAIO VPCEB4S1E Инструкция по эксплуатации
- Zalman ZM700-SV Инструкция по эксплуатации
- Leica X Black Инструкция по эксплуатации
- Sony VAIO VPCEB4M1R Инструкция по эксплуатации
- Leica X Silver Инструкция по эксплуатации
- Zalman ZM500-LX Инструкция по эксплуатации
- Sony VAIO VPCEB4M1E Инструкция по эксплуатации
- Zalman ZM600-LX Инструкция по эксплуатации
- Sony Alpha A5100 Kit 16-50 Black Инструкция по эксплуатации
- Sony VAIO VPCEB4L9E Инструкция по эксплуатации
- Sony Alpha A5100 Kit 16-50 White Инструкция по эксплуатации
- Zalman ZM600-LE Инструкция по эксплуатации
- Sony VAIO VPCEB4L1R Инструкция по эксплуатации
- Case Logic TBC406K Bl Инструкция по эксплуатации
- Zalman ZM500-GSII Инструкция по эксплуатации
- Sony VAIO VPCEB4L1E Инструкция по эксплуатации
- Riva 7211 Grey Инструкция по эксплуатации
Скачать
Случайные обсуждения
Ответы 1
Из за чего может не работать бп zalman zm400, после резкого отключения электричества
8 лет назад